ECHO TEC. WATERMAKER LIMITED WARRANTY 

 

Echo Marine Ltd. warrants to the original purchaser for a period of twelve (12) months from the date of 
shipment  that  the  ECHO  Tec.  watermaker  will  perform  according  to  specifications.    Echo  Marine’s 
liability under this warranty shall be limited to repair or replacement of the ECHO Tec. watermaker at 
Echo  Marine’s  option.  Under  no  circumstances  shall  Echo  Marine  Ltd.  be  liable  for  consequential 
damages  arising  out  of  or  in  any  way  connected  with  the  failure  of  the  system  to  perform  as  set  forth 
herein.  This limited warranty is in lieu of all other expressed or implied warranties, including those of 
merchantability and fitness for a particular purpose. 
 
 
In the event of a defect, malfunction, or failure during the warranty period, Echo Marine Ltd. will repair 
or  replace,  at  its  option,  the  product  or  component  therein  which,  upon  examination  by  Echo  Marine, 
shall appear to be defective, or not up to factory specifications. 
 
 
To  obtain  warranty  service,  the  defective  product  or  part  must  be  returned  to  Echo  Marine’s  Service 
Center.  The purchaser must pay any transportation or labor expenses incurred in removing and returning 
the product to the service center. 
 
 
The  limited  warranty  does  not  extend  to  any  system  component  which  has  been  subjected  to  misuse, 
neglect, accident, improper customer installation, or used in violation of instructions furnished by Echo 
Marine Ltd.  The warranty does not extend to components on which the serial number has been removed, 
defaced or changed. 
 
 
Echo Marine Ltd. reserves the right to make changes or improvements in its product during subsequent 
production  without  incurring  the  obligation  to  install  such  changes  or  improvements  on  previously 
manufactured equipment. 
 
 
The implied warranties, which the law imposes on the sale of this product, are expressly LIMITED, in 
duration  to  the  time  period  above.    Echo  Marine  shall  not  be  liable  for  damages,  consequential  or 
otherwise,  resulting  from  the  use  and  operation  of  this  product  or  from  the  breach  of  this  LIMITED 
WARRANTY. 
 
This limited warranty service does not apply to normal recurring user maintenance as described below. 
 
 

  Pre-filter Cartridges    

 

  Pump Valve Assemblies 

 

  Pump Seals   

 

 

  Gauge Instrument Calibration 

 

  Pump Packings 

 

 

  Pump Crankcase Oil 

 

   

           

All manuals and user guides at all-guides.com

all-guides.com

Содержание 1200-PRO- 3

Страница 1: ...NS 6 7 OPERATION INSTRUCTIONS 8 MEMBRANE CLEANING PROCEDURE 9 MAINTENANCE TIMETABLE 10 PRESSURE VESSEL ENDPLUG CHANGING PROCEDURE 11 ELECTRICAL DIAGRAM 12 TROUBLESHOOTING GUIDE 13 14 HIGH PRESSURE PUM...

Страница 2: ...on system By understanding the function importance and normal operation of each part in the system the operator can readily diagnose problems when they first develop Such problems are easily corrected...

Страница 3: ...hin film composite spiral wound single pass reverse osmosis element Salt Rejection min 99 5 Salinity Range System 500 900 up to 50 000 ppm TDS NaCl 1200 up to 40 000 ppm TDS NaCl 1500 up to 36 000 ppm...

Страница 4: ...cartridge filtration system 2 1 Fresh water flush kit with hose and 316SS hose clamps 3 1 Product water tube 10ft 3m 1 Reject hose 10ft 3m with 2pcs 316SS hose clamps 1 Intake hose 10ft 3m with 2pcs...

Страница 5: ...take of the desalination system located at the pre filter assembly Secure all hoses with the supplied hose clamps PRODUCT WATER TUBING Connect the product water outlet marked SAMPLE with a test statio...

Страница 6: ...the electrical control panel to the FEED position feed pump only and purge the system until all entrapped air has escaped 6 In the AUTO position press the START button until the pressure on the low p...

Страница 7: ...lve and the seacock MEMBRANE STORAGE PROCEDURE If you intend to store your watermaker for more than ten days growth of microorganism will degrade the RO membranes performance The RO membranes should b...

Страница 8: ...rning label on side of container and observe all safety precautions on label CAUTION Do not mix different cleaning chemicals together Do not use different cleaning chemicals together at the same time...

Страница 9: ...rs or when clogged Pre filters Replace or clean elements and clean housings When system intake pressure drops below 5psi Charcoal flush filter Replace element Every 6 months High pressure pump Change...

Страница 10: ...it in one fast pull 6 Inspect the end plug for hairline cracks or damages on the O rings and O ring grooves 7 Pull the membrane on the product pipe out of the pressure vessel or remove both plugs and...

Страница 11: ...BUTTON NO SELECTOR SWITCH S2 3 POSITION MAINT 4 CONTACTS NO T1 HIGH PRESS SWITCH S4 NC LOW PRESS SWITCH S5 NO TANK FULL SWITCH S6 NC EXTERNAL MAIN IN ELECTRICAL DIAGRAM CONTROL BOX ECHOTEC PRO BHL SER...

Страница 12: ...ilter s Inability to Discharge valve chamber Allow more time to prime build up pressure has air trapped within it and ensure that there are no air suction leaks Open valve chambers and allow air to es...

Страница 13: ...6D and clean the old Locktite from the plunger bolt 16C and plunger base 16A Replace the plunger with the new one and Locktite the plunger bolt and torque to 120 inch pounds NOTE If there are deposits...

Страница 14: ...ere removed from the crankshaft Be certain the bearings are pressed all the way onto the shaft and completely into the crankcase Replace radial shaft seal 11 bearing cover with sight glass 7 and 8 and...

Страница 15: ...All manuals and user guides at all guides com...

Страница 16: ...The purchaser must pay any transportation or labor expenses incurred in removing and returning the product to the service center The limited warranty does not extend to any system component which has...

Страница 17: ...uling rust chemical attack extreme temperatures over 113 F under 33 F drying out or extreme pressures over 1000 psig CAUTION Use of parts not supplied directly by Echo Marine generic parts including b...

Отзывы: