2
Sensor Layout:
LED
FLASHES
DURING
PWR
UP.
ON
DURING
DETECTION.
SENSITIVITY
ADJUSTMENT
(POTENTIOMETER)
POLARIZED
CONNECTOR
_______________________
BROWN
GREEN
WHITE}
RELAY
– COMMON
YELLOW}
RELAY
– NO
}
PWR
PLANAR
ANTENNA
Figure 2
Installation Tips:
-
Mount to a secure surface that is not subject to motion or vibration.
-
Do not mount behind a metal surface.
-
Avoid moving objects (examples: wind blown curtains or an oscillating fan) within the target path.
-
Avoid HF lamps or fluorescent lighting in close proximity of the sensor.
-
Avoid touching the electronic circuit board, which is susceptible to electrostatic discharge.
-
Use the included template for identifying the placement of the securing screws.
-
To remove the cover from the mounting plate, gently pry it with a small flat blade screwdriver at the back
center joint right below the LED window.
-
Use the grommet holes for passing the cable through and tuck into the recessed area in the back of the
mounting plate before it exits one of the two holes provided for that purpose. Do not bend the cable sharply,
but rather leave a gentle service loop in the cable from the circuit board connection as it is routed through
the grommet hole. We suggest using a zip tie as strain relief to prevent pulling the service loop too tight.
See Fig. 3 for the service loop and zip tie and Fig. 4 for routing on the aft side of the mounting plate.