background image

13

OPeRATiOn

inTROducTiOn

This operation procedure guides you through a typical process on how to set a M.O.L.E.® Ther

-

mal Profiler up for performing a OvenRIDER® NL 2+ data run. For additional detail, consult the 

Help System in the software.

The M.O.L.E.® Thermal Profiler depends on the MAP (Machine-Assembly-Process) software to 

control how it collects and interprets data. Several kinds of data runs may need to be performed 

to achieve desired information, or the same data run may be performed repeatedly over time to 

monitor one process. Either way, each data run must be set up at least once.

The MAP software includes wizards that help you get started quickly, even if you are a beginner 

or infrequent user.

Содержание OvenRIDER NL2+

Страница 1: ...Quick Reference Guide ...

Страница 2: ...IONS 3 SETUP 4 CHARGING THE POWER PACK 4 SOFTWARE INSTALLATION 6 SOFTWARE REGISTRATION 8 COMMUNICATIONSv9 ZONE BOUNDARY MAGNET INSTALLATION 11 OPERATION 13 INTRODUCTION 13 STEP 1 SETUP INSTRUMENT 14 STEP 2 DATA COLLECTION 19 STEP 3 DOWNLOAD DATA 22 ...

Страница 3: ...p communications and operation For detailed information on both Hardware Software components please refer to the Help system accessible in the M O L E MAP Software To access the help system start the software and use any of the methods listed Select the Help Button on the Toolbar Pressing the shortcut key F1 On the Help menu click MAP Help ...

Страница 4: ...r light Zone Sensor Light This light illuminates when the detects zone boundary magnets Thermal Barrier This is the protective Ther mal Barrier for the M O L E Profiler Connector Bridge This is where the M O L E Profiler plugs into the RIDER Barrier Locking Latch Secures the cover of the barrier to prevent it from opening Extractor Handle This disconnects the M O L E Profiler from the connector br...

Страница 5: ...d For quick charges it can be charged for 15 minutes allowing one 10 minute data run to be performed 4 SETUP CHARGING THE POWER PACK 1 Insert the USB cable male series A plug into a computer USB Port 2 Insert the USB cable male series B mini plug into the Data Charging Port ...

Страница 6: ...THE POWER PACK 1 Remove the Power Pack 2 Plug the transformer end of the charger into a 120 or 230VAC wall outlet and the connector end into the Power Pack 3 Once charged reconnect to the M O L E Profiler The activity light flash es once indicating the M O L E Profiler is ready to collect data ...

Страница 7: ...SB Port and the AutoPlay menu appears 2 Select Open folder to view files but ton on the AutoPlay menu to launch Windows Explorer Closely follow the instructions for your operating system For detailed information view the Instal lation Help file on the Flash Drive ...

Страница 8: ...s for the computer to in stall and register the software To install as administrator locate the setup exe on the installation drive Right click the file to display the shortcut menu and select Run as ad ministrator 7 SETUP SOFTWARE INSTALLATION ...

Страница 9: ...ation supplied on the dialog box contact ECD 1 On the Help menu click Register and the dialog box appears 2 Select Online Registration and enter the required information on the M O L E MAP Software Registration form 3 Enter the 16 digit Unlock Key and then the Register command button to com plete the software Registration ...

Страница 10: ...desktop This panel displays the four most common MAP commands 9 SETUP COMMUNICATIONS 1 Plug the computer interface cable into a computer COM Port and the other end into the M O L E Profiler Data Port 2 On the M O L E menu click the Select Instrument command USB RS 232 Adaptor B mini plug A plug ...

Страница 11: ...t M O L E Profiler if it used again on the same COM port 10 SETUP COMMUNICATIONS 3 Select the desired instrument from the dialog box If there are none displayed click the Scan for Instruments command button to detect all available instru ments 4 Click the OK command button to accept ...

Страница 12: ... to the clips may be necessary to properly mount magnets 2 Open the top of the oven and determine where to place the start of the first zone magnet 3 Adjust the conveyor to match the RIDER width The width of the pallet is engraved on the back edge of the pallet top 4 Slide the RIDER on the conveyor until the front sensor reaches the magnet 5 Center a magnet and clip on the first zone boundary with...

Страница 13: ... double flash If this occurs the magnet is placed to close to the pallet sensor 6 When the magnet is properly aligned mount the P clip securely by tapping and drilling for a 6 or 8 screw If the OMNI FLO clip is being used clip it to the rail and slide it into the desired position Using the Manual Zone feature in the software you can make an oven model by mea suring from the magnet to the center be...

Страница 14: ...Thermal Profiler depends on the MAP Machine Assembly Process software to control how it collects and interprets data Several kinds of data runs may need to be performed to achieve desired information or the same data run may be performed repeatedly over time to monitor one process Either way each data run must be set up at least once The MAP software includes wizards that help you get started quic...

Страница 15: ... O L E Thermal Profiler to the computer 3 Make sure the M O L E Power Pack battery is fully charged When a M O L E Thermal Profiler is se lected the software status bar displays the current battery voltage 4 Set an OvenRIDER NL 2 Environment Either open an existing Environment Folder or create a new one ...

Страница 16: ...left of the dialog box uses a color key to inform the user of the progression through the wizard Current Completed Remaining 15 OPERATION SETUP INSTRUMENT 5 On the M O L E menu select Setup Instrument and the workflow wizard appears 6 Set the Instrument Name ...

Страница 17: ...re command button 16 OPERATION SETUP INSTRUMENT 7 Select the Sensor Platform button 8 Select the OvenRIDER NL 2 then the OK com mand button to proceed 9 Confirm the settings and then select the Next command button to send the data listed in the dialog box to the instrument ...

Страница 18: ... 17 OPERATION SETUP INSTRUMENT 10 Confirm the assembly information 11 Click the Next command button ...

Страница 19: ...od data they are high lighted and a RED sign is displayed 18 OPERATION SETUP INSTRUMENT 12 Verify the instrument status This dialog box displays the health of the M O L E Profiler such as battery charge internal temperature thermocou ple temperatures 13 Select the Finish command button to complete the Setup Instrument wizard ...

Страница 20: ...used by exceed ing the maximum specified internal tem perature 19 OPERATION DATA COLLECTION STEP 2 DATA COLLECTION 1 Set the width of the conveyor to match the RIDER 2 Set the oven as you normally would for a common product i e zone temperatures conveyor speed 3 Connect the M O L E Profiler to the connector bridge in the Thermal Barrier Turn it ON and press the RECORD button ...

Страница 21: ...sure the RIDER is fed into the machine in the proper direction There are two arrows on the RIDER barrier that indicates the prop er direction 6 When the RIDER has traveled through the oven use protective gloves to retrieve it from the conveyor The best way to do so is to grasp it by the front carrying handle ...

Страница 22: ...er to rise above operating tem perature specification 21 OPERATION DATA COLLECTION 7 Open the Thermal Barrier and if the Record button is still flashing this means the M O L E Profiler is still logging and it should be stopped 8 Remove the M O L E Profiler from the Thermal Barrier by pulling the extractor handle up Wait a few minutes for the M O L E Profiler to cool Handle it carefully as the case...

Страница 23: ...AD DATA STEP 3 DOWNLOAD DATA 1 Connect the M O L E Thermal Profiler to a computer and the AutoPlay panel appears in the lower right corner of the desktop 2 Select the Read Instrument command and the workflow wizard appears ...

Страница 24: ...oes not delete any data run files in the previ ously set Environment Folder and can be quickly accessed using the Recent Environment Folders on the File menu or Welcome Worksheet 23 OPERATION DOWNLOAD DATA 3 Select the desired data run from the M O L E memory list and then click the Finish com mand button to complete the wizard and read the data run from the M O L E Profiler ...

Страница 25: ...d be in locations such as My Docs Windows XP Li braries Documents Winows 7 8 24 4 When the data run has been downloaded the software will prompt the user to name and save the data run file XMG 5 The information is automatically saved in the data run file XMG and the experiment data can now be analyzed with the software tools OPERATION DOWNLOAD DATA ...

Страница 26: ...CD Asia Pacific Singapore Mobile 65 9692 6822 Fax 65 6241 9890 E Mail ecd asia ecd com ECD Europe Africa Middle East Mobile 48 512 659 100 E Mail ecd europe ecd com 2007 2019 ECD All Rights Reserved Foreign and US Products of ECD are covered by US Patents and Patents Pending The trapezoidal ECD logo OvenRIDER NL 2 and M O L E Multi Channel Occurrent Logger Evaluator are registered trademarks of EC...

Отзывы: