Eccotemp EZ-Flush i12 Скачать руководство пользователя страница 27

25

Product Support: Eccotemp.com/help-desk            Shop Online: Eccotemp.com/products          Store Locater: Eccotemp.com/locater

Phone: 866-356-1992 | Email: [email protected] | Address: 315 - A Industrial RD Summerville, SC 29483

PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM 

FOR ALL OF OUR PRODUCT MANUALS.

PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.

Set Temperature Memory:

•  This water heater contains an electronically controlled 

thermostat. From the factory, the temperature range 

is between 90°F and 140°F.

•  The remote control is factory preset to 110°F.

•  To turn the remote control ON or OFF, press the 

POWER button for more than 3 seconds.

•  To adjust the temperature to a required setting, 

in“priority” mode, press the UP or DOWN temperature 

button. Press and hold UP or DOWN to raise or lower 

the temperature continuously.

•  When the unit is in use, the set temperature can 

increase to 122°F, but there is no limit to temperature 

decrease. To increase the temperature more than 

122°F, the water will need to be shut off first.

NOTICE: If inlet water temperature is high, and set temperature 

is low, the actual temperature might be higher than the set 

temperature, and vice versa..

        DANGER: There is a hot water 

scald potential if the temperature 
is set too high. Households with 
small children, disabled, or elderly 
persons may require a 120°F. or 
lower temperature setting to prevent 

contact with HOT water.

Output temperature of water is regulated by setting 

the temperature on the front of the remote control.

Safety factors should be considered when selecting 

the water temperature setting of the water heater’s 

remote control. The remote control was set at 110°F 

before the water heater was shipped from the factory. 

This is the recommended starting point.

Water temperatures above 120°F can cause severe 

burns or death from scalding. The thermostat is 

adjusted to its lowest temperature position when 

shipped from the factory.

Be sure to read and follow the warnings outlined in this 

manual and on the label located on the water heater. 

Mixing valves are available for reducing point of use 

water temperature by mixing hot and cold water in 

branch water lines.

Procedures for adjusting the thermostat for energy 

efficient operation at the minimum water temperature 

setting consistent with the consumer’s needs.

Contact a licensed plumber or the local plumbing 

authority for further information. See page 4 for 

details.

Water Temperature Setting

Water Temperature

120°F
125°F
130°F
135°F
140°F
145°F
150°F
155°F

Time To Produce a Serious Burn

More than 5 minutes

1 1/2to 2 minutes

About 30 seconds

About 10 seconds

Less than 5 seconds
Less than 3 seconds

About 1 1/2 seconds

About 1 second

Table courtesy of Shriners Burn Institute

•  The display will read the set temperature if the water 

heater is not in use or there is no water flow. If the 

water heater is in use or has water flow, the display 

will read the actual temperature. To view the set 

temperature in this condition, press UP or DOWN and 

the set temperature will flash for 3 seconds.

•  The hottest temperature water will be at the hot water 

faucet closest to the water heater

•  Always remember to test the water temperature with 

your hand before use and remember that hotter water 

increases the risk of scald injury.

•  Always supervise young children or others who are 

incapacitated.

• 

If the water heater has been subjected to fire, flood 

or physical damage, turn off the manual gas shut-off 

valve(s), and do not operate the water heater again 

until it has been checked by qualified personnel.

      

WARNING: Should overheating occur or the gas supply fail to shut off, turn off the manual gas 

control valve to the appliance.

Содержание EZ-Flush i12

Страница 1: ......

Страница 2: ...ation of the heater in the location speci ed by the manufacturer Local codes shall govern installation of relief devices For safe operation of the water heater the relief valve must not be removed or...

Страница 3: ...ithin it seek professional advice Any questions regarding the operation maintenance service or warranty of this water heater should be directed to the seller from whom it was purchased If additional i...

Страница 4: ...There are many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol Recognize this symbol as an indication of Importa...

Страница 5: ...at initial start up and at least annually thereafter Refer to the Care and Cleaning section of this manual for more information regarding flue terminal inspection WARNING Gasoline as well as other fl...

Страница 6: ...is on To find water temperature being delivered turn on a hot water faucet and place a thermometer in the water stream and read the thermometer The temperature of the water at the outlet of the water...

Страница 7: ...ury or fire do not connect the water heater to a fuel type not in accordance with the unit data plate propane for propane units and natural gas for natural gas units These units are not certified for...

Страница 8: ...cable local codes shall govern installation For residential water heaters of a capacity greater than 52 gallons or tankless style consult the local building jurisdiction code for acceptable bracing pr...

Страница 9: ...ng must be provided The unit should not be installed in the same room with a gas stove When determining the floor clearance a clearance of 6 inches must be maintained between the vent pipe and combust...

Страница 10: ...lines should be insulated to conserve water and energy The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc The water heater shoul...

Страница 11: ...oors each opening must have a minimum net free area of not less than one square inch per 2 000 Btuh of the total input rating of all the appliances in the enclosure If ducts are used the minimum dimen...

Страница 12: ...5 gpm Additional water pressure is required for long pipe runs and outlet fitting s water pressure drops To maintain proper performance ensure sufficient water supply pressure The Required Water Press...

Страница 13: ...led between the relief valve and the water heater Discharge from the relief valve should be piped to a suitable drain to eliminate potential water damage Piping used should be of a type approved for t...

Страница 14: ...s than psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test p...

Страница 15: ...TO DATE PLEASE VISIT OUR HELPDESK AT WWW ECCOTEMP COM FOR ALL OF OUR PRODUCT MANUALS PLEASE NOTE THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY NOTICE The National Fuel Gas Code NFGC mandates a...

Страница 16: ...oles in the water heater onto the expansion screws hang it up and screw the nuts tightly 2 Put the vent pipe through the holes in the wall and connect the elbow with the water heater and vent pipe C V...

Страница 17: ...t Support isolation hanging bands should be used DO NOT use wire See diagram below DANGER Failure to install the vent adapter and properly vent the water heater to the outdoors as outlined in the Vent...

Страница 18: ...n of the unit is evacuated from the appliance A 1 4 per foot upward slope is acceptable when it is not possible to vent with a downward slope however a approved Category III Stainless Steel condensate...

Страница 19: ...ling the water heater Continued US Installations1 Canadian Installations2 A Clearance above grade veranda porch deck or balcony 12 in 30 cm 12 in 30 cm B Clearance to window or door that may be opened...

Страница 20: ...kW 12 in 30 cm for appliances 10 000 Btuh 3kW and 100 000 Btuh 30 kW 36 in 91 cm for appliances 100 000 Btuh 30 kW K Clearance to a mechanical air supply inlet 3 ft 91 cm above if within 10 ft 3 m ho...

Страница 21: ...COM FOR ALL OF OUR PRODUCT MANUALS PLEASE NOTE THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY Installing the water heater Continued WARNING Use UL approved Category III vent material only No ot...

Страница 22: ...found inside of the cover panel A green screw is provided in the junction box for grounding connection Connect the live wire to black leg wire and the neutral wire to the white neutral wire Electrica...

Страница 23: ...structions included with the kit must be carefully followed Insulation Blankets Hot and Cold Pipe Insulation Installation For increased energy efficiency use pipe insulation Please install the insulat...

Страница 24: ...oom to service heater Combustible materials such as clothing cleaning materials rags etc clear of the heater and vent piping Water heater is properly attached to the wall B Water Supply Water supply h...

Страница 25: ...ight any appliance DO NOT touch any electric switch DO NOT use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you canno...

Страница 26: ...ner still fails to ignite turn off the faucet and wait for 10 20 seconds and repeat the above procedures For first use and or if the water heater has not been used for a considerable period of time th...

Страница 27: ...hipped from the factory This is the recommended starting point Water temperatures above 120 F can cause severe burns or death from scalding The thermostat is adjusted to its lowest temperature positio...

Страница 28: ...uld be cleaned monthly Refer to the Housekeeping section for further information DO NOT operate the water heater if you feel something is wrong with the unit DO NOT allow children to operate or otherw...

Страница 29: ...rate the unit if vent system shows signs of leaking exhaust Check to make sure that the Air Intake and the vent terminal have not been blocked or contain debris Vacation and Extended Shut Down If the...

Страница 30: ...F position and disconnect breaker at least 10 seconds after step 1 5 Open drain valve 6 Open all hot water faucets Before proceeding to the next step make sure that COLD water is coming out of all hot...

Страница 31: ...hutoff valve and open fully Hot water faucet is not fully opened Open hot water faucet completely The main burner goes off when incoming water volume is inadequate Water piping is frozen Allow piping...

Страница 32: ...olenoid valve Open circuit of the valve short circuit of the valve none of the above Connect the valve replace the valve replace the computer board If the error code remains shown Close the hot water...

Страница 33: ...ame sensor Flame sensor board Solenoid valve Gas inlet pipe Back cover Power cord Gas flute Water inlet pipe Computer board Wind switch Clip Hot water temp sensor Replacement Parts For models using na...

Страница 34: ...UENTIAL DAMAGES Limited Warranty Period This Warranty is extended by Eccotemp Systems to the Owner This warranty takes effect on the date of installation of the Product or 30 days after the date of pu...

Страница 35: ...cing the unit shipping delivery and handling of the replacement part cost for permits or materials necessary for the repair or incidental costs resulting from damage external to the unit resulting fro...

Страница 36: ......

Отзывы: