background image

2

Product Support: Eccotemp.com/help-desk            

Phone: 866-356-1992 | Email: [email protected] | Address: 315 - A Industrial RD Summerville, SC 29483

Important:

Eccotemp EZ-Flush System Descaler Kit has been designed to work in conjunction with isolation valves that provide 3’4” hot and 

cold service connections. If these valves have not been installed on your heater then the heater must be disconnected from the 

plumbing and drained, and the Eccotemp EZ-Flush System Descaler Kit must be connected directly to the cold and hot water 

connections. Eccotemp EZ-Flush System Descaler Kit is NSF approved and safe to dispose of in drains*

Whats Included:

EZ-Flush System Descaler Kit

built in pump

1 QT. liquid descaler solution

(2) 5’ rubber hoses

Recommended Uses:

Ice Machines, Humidifiers, Water Heaters, Boilers, Heat Exchangers, Chillers, 

Vacuum Pumps, Condensers, Evaporators, Tanks, Potable Waterlines, and Water 

Operated Equipment. 

Descaling Instructions: 

      PLEASE NOTE:

 The Eccotemp EZ-Flush System

      Descaler Kit 

MUST

 be on a flat, even surface before use. 

1. Disconnect power to water heater

2. Close hot and cold isolation and service valves and

remove the service caps.

3. Connect one hose to the water outlet labeled “ OUTLET”

and the other end of the same hose to cold service

valve.

4. Connect one hose to the water inlet labeled “INLET” and

the other end of the same hose to hot service valve.

5. Pour one gallon of water along with contents of 1 quart

Eccotemp Descaler into the EZ-Flush System Descaler Kit.

      PLEASE NOTE: 

add additional water if needed to ensure

      free flow recirculation.

6. Open both hot and cold service valves.

7. Plug Eccotemp EZ-Flush System Descaler Kit into

grounded receptacle.

8. Turn the Eccotemp EZ-Flush System Descaler Kit to the

on position labeled “ON”.  Never allow pump to run

without adequate liquid in bucket or damage to the

pump will occur.

9. Allow pump to circulate Eccotemp EZ-Flush System

Descaler Kit solution through heater for 30-45 minutes.

10. Turn Eccotemp EZ-Flush System Descaler Kit to the off

position labeled “OFF”.

11. Close cold service valve. Remove hose from cold

service valve, and replace service cap.

12. Disconnect the hose from the water inlet labeled

“INLET”. Discard Eccotemp EZ-Flush System Descaler

Kit Solution*.

13. Disconnect the hose from the outlet labeled “OUTLET”.

14. Flush System for 3-5 minutes or until water flows

clear by opening the cold isolation valve and allowing

water to exit through the hot service valve into a drain

or bucket, empty as needed during the process.

15. Close hot service valve. Remove hose from hot service

valve and replace service cap; then open hot isolation

valve.

16. Connect power to water heater and return application

to service.

       PLEASE NOTE:

 The Eccotemp EZ-Flush System

       Descaler Kit 

MUST

 be on a flat, even surface before use.

Warning:

THE ECCOTEMP EZ FLUSH SYSTEM DESCALER KIT 

MUST

 BE ON A FLAT, EVEN SURFACE BEFORE USE.

Downloaded from https://gadgetsgo.com/Eccotemp-EZ-KIT-Descaling-cleaner-system.html Authorized Eccotemp Distributor

Содержание EZ-Flush fvi12

Страница 1: ...Downloaded from https gadgetsgo com Eccotemp EZ KIT Descaling cleaner system html Authorized Eccotemp Distributor...

Страница 2: ...along with contents of 1 quart Eccotemp Descaler into the EZ Flush System Descaler Kit PLEASE NOTE add additional water if needed to ensure free flow recirculation 6 Open both hot and cold service va...

Страница 3: ...its component parts has been subject to misuse alteration neglect or accident or b The EZ Flush system descaler kit has not been operated in accordance with the printed manufacturer s instructions 5 T...

Страница 4: ...RISONS fvi12 INDOOR ONLY 80 000 3 GPM No 120 VAC available in NG LP 2 5 horizontal Venting Incl 20 80 PSI Flow activated Not Included Automatic 80 120 2 Years limited 14 x 5 x 24 30 lbs 17 x 11 x 29 3...

Страница 5: ...si es necesario para asegurar el libre flujo de recirculaci n 6 V lvulasde servicio abierto fr os y calientes 7 Sistema de enchufe del kit Eccotemp Descaler en el recept culo con conexi n a tierra 8...

Страница 6: ...mal uso alteraci n negligencia o accidente o b El kit descalcificador sistema EZ Flush no ha sido operado de acuerdo con las instrucciones del fabricante impreso 5 El due o y no el fabricante o su rep...

Страница 7: ...aci n horizontal Incl 20 80 PSI Flow activada No incluido Autom ticas 80 120 2 a os limitada 14 x 5 x 24 30 lbs 17 x 11 x 29 32 lbs i12 EXTERIORES 140 000 6 8 GPM No 120 VAC disponible en gas natural...

Страница 8: ...de 1 quart Eccotemp d tartrant dans le Kit Eccotemp syst me d tartrant S IL VOUS PLA T NOTE ajouter de l eau si n cessaire pour assurer la recirculation d coulement libre 6 Ouvrez les vannes la fois c...

Страница 9: ...tion de modification de n gligence ou d un accident ou b Le kit de d tartrage du syst me EZ Flush n a pas t utilis conform ment aux instructions du fabricant imprim 5 Le PROPRI TAIRE et non pas le fab...

Страница 10: ...NG LP 2 5 vacuation horizontale Incl 20 80 PSI d bit activ Non inclus Automatique 80 120 2 ans limit e 14 x 5 x 24 30 lb 17 x 11 x 29 32 lbs i12 EXT RIEUR SEULEMENT 140 000 6 8 GPM Non 120 VAC dispon...

Страница 11: ...Product Support Eccotemp com help desk Phone 866 356 1992 Email Support eccotemp com Address 315 A Industrial RD Summerville SC 29483...

Страница 12: ...Downloaded from https gadgetsgo com Eccotemp EZ KIT Descaling cleaner system html Authorized Eccotemp Distributor...

Отзывы: