Installing the water heater, Continued....
Installation Standards
A =
Clearance above grade,
veranda, porch, deck, or
balcony
12 in (30 cm)
12 in (30 cm)
B =
Clearance to window or
door that may be opened
4 ft (1.2 m) below or to side
of opening; 1 ft (300 mm)
above opening
6 in (15 cm) for appliances
≤
10,000 Btuh (3 kW), 12 in (30
cm) for appliances > 10,000
Btuh (3 kW) and
≤
100,000
Btuh (30 kW), 36 in
(91 cm) for appliance >
100,000 Btuh (30 kW)
C =
Clearance to permanently
closed window
*
D =
Vertical clearance to
ventilated soffit located
above the terminal within
a horizontal distance of
2 feet (61 cm) from the
center line of the terminal
*
E =
Clearance to unventilated
soffit
*