Bracket Mounting:

1. Select a mounting location for the unit on a flat surface and drill a 15/32”

hole.

2. Secure the light head with the supplied hardware by using the M5 screws

and lock washers as shown in Figures 2 or 3.

Aiming Instructions:

Installer is responsible for ensuring the snowplow lights are aimed properly

such that beams comply with current highway regulations.  Beams should

project the same distance ahead as compliant OEM headlights.

FIGURE 2

MOUNTING SURFACE

Wiring Instructions:

The wiring configuration is as shown in Figure 4.  All wiring should be a 

minimum of 16 AWG.  The positive line must have a slow blow 25 or 30 

amp fuse.  Routing the ground wire directly back to negative battery ter-

minal is recommended.  Pack dielectric grease, such as Dow Corning 

4, around each electric connection exposed to moisture or the ambient 

environment.

 

Important! Disable power before wiring the product.

Indicator Installation:

Each kit includes 1 indicator light per flood light which can be installed

on top or either side.

To assemble the indicator on the flood light, start by removing the M3

screws and indicator port cover.  Connect the indicator wires to the flood 

light and cover the connection in dielectric grease to reduce exposure to 

the elements.

Install the indicator as shown in Figure 1 and secure in place with the 

two M4 screws included using a 3mm hex key.
NOTE: The amber indicator functions only as a turn signal.

FIGURE 1

FIGURE 4

Ground (-) (Black)

High Beams (Red)

Low Beams (Yellow)

Parking Light (Green)

Indicator Light (Grey)

25A In-line

Fuse

Ignition

Switch