L-Bracket Mounting:

1. Mark drill hole locations on the mounting surface using the 

short leg of the bracket as a template.

2. Drill mounting holes using a 3.74 mm drill bit. Drill a 10 mm 

hole for routing the wires as needed. 

3. Attach the bracket to the directional with the supplied 

machine screws.

4. Mount the directional and bracket to the mounting surface, 

routing the wires through the 10 mm hole using additional 

grommets or cable protection as necessary to protect the 

wiring from any sharp edges. Secure the directional to the 

surface using the supplied thread forming screws. See 

Figure 1.

Wiring Instructions:

Important!

 

 This unit is a safety device and it must 

be connected to its own separate, fused power point 

to assure its continued operation should any other 

electrical accessory fail.

Flash Pattern Selection:

The ED3779 series directionals can be configured to flash the

following patterns (in the order below) by momentarily applying

ground to the blue wire. The directional must be powered

through the ground and power wires to allow pattern selection.

The ED3779 Series of directional LED light heads are self 

flashing. All wiring should be a minimum of 20 AWG. The 

positive line must have an in-line 3 amp slow-blow fuse for each 

directional as shown. Set each unit to the same flash pattern 

before syncing. Synced units will flash simultaneously when set 

to the same phase or alternating when set to A and B. Note: 

Only flash patterns with an A or B phase identified are capable 

of being synced. Isolate the yellow and blue wires when not in 

use.

YELLOW -

(SYNC)

+

-

BLACK - GROUND

BLUE - 

FLASH PATTERN

SELECT (MOMENTARY TO (-))

DIM (+)

RED - COLOR 1

SWITCH

(USER SUPPLIED)

IN-LINE FUSE

(USER SUPPLIED)

WHITE -

COLOR 2 (DUAL

COLOR ONLY)

SWITCH

(USER SUPPLIED)

SWITCH

(USER SUPPLIED)

ORANGE - 

TAKDOWN

FIGURE 2

FIGURE 1