Changing the default programming password code by SMS
In order to change the “password programming code” you need to send an SMS with the following structure:
P.1234NP.1111
P.1234 (the default code) required for any SMS command
The letters NP stands for “New Password” then the numbers 1111 are the new password
which should be used from now on in any program SMS you send to the unit. "P.1111"
Gate Opening trigger Delay
The default pulse trigger of the internal; relay is 3 seconds. In order to change the trigger opening time
of the relay to 1 seconds (for example), send SMS with the following structure
P.1234GOD.1,1,1,1
The Maximum time of the relay to stay open is 60 second
Info
In order to receive information on the numbers and special numbers stored in unit’s memory send the
following SMS command:
P.1234INFO
Disable/Enable the unit
The unit default status is enabled. In order to disable the unit send the following SMS
P.1234EN.0
I
n order to enable the unit to function send
P.1234EN.1
Open All
The "Open All" feature will allow the gate to open for any one that calls the unit.
To enable this feature send SMS
P.1234open.1
To disable this feature send
P.1234open.0
REST
In order to reset the unit send the following
P.1234RESET