22
9.3- Electrical Connection
Electrical installation must be made according to the national and local instructions. The boiler must be
earthed and a standard 230 V AC – 50 Hz supply is required.
CAUTION:
Disconnect power supply to prevent electrical shock before
connecting the electrical supply.
CAUTION:
If the supply cord is damaged, it must be replaced by the
manufacture, its service agent or similarly qualified person in order to avoid a hazard.
CAUTION:
The 2-amp bipolar fuse with a minimum contact opening of 3 mm must be
used in the electrical connection of the boiler.
CAUTION:
The cable diameter (including insulation) of the electrical installation to be
installed must be at least 14 mm and the pipe diameter used must be at least 16 mm.
Содержание CONFEO PREMIX P 14 HCH
Страница 2: ......
Страница 13: ...13 5 5 Electrical Diagram...
Страница 16: ...16 Figure 6 7 3 Distances for Placement of Flues Figure 7...
Страница 37: ...37 15 INSTALLATION TEMPLATE 15 1 HM Model...
Страница 38: ...38 15 2 HCH Model...
Страница 39: ...39 15 3 HST Model...
Страница 43: ......
Страница 45: ......
Страница 46: ......