2.3 Device default parameter test steps
Different channels use the same IP but different local ports. For example, the factory-configured channel 1
corresponds to port 8001, and channel 2 corresponds to port 8002. For details, see the chapter "Correspondence
Between Channels and Serial Ports".
2.3.1 Hardware connection
1. Connect the serial port server network port and the computer network port with a network cable;
2. Use a USB to RS485 serial cable to connect the USB port of the computer to any RS485 port of the serial server;
3. Use the power adapter (DC 8-28V) to power on the device, and observe whether the indicator light is normal,
refer to "indicator light description";
4. After confirming that there is no problem with the status, proceed to the next step of configuration;
2.3.2 Device parameter configuration
In order to let users have a simple understanding of the serial server, we use the default parameters of the serial
server to conduct data transparent transmission tests. The default parameters of NB124S serial server device are
shown in the table below.