Chengdu Ebyte Electronic Technology Co., Ltd
Copyright ©2012-2023, Chengdu Ebyte Electronic Technology
Co., Ltd
17
Chapter 6 Frequently asked questions
6.1 Unsatisfactory transmission distance
When there is a straight-line communication barrier, the communication distance is attenuated accordingly;
Temperature, humidity, and co-channel interference can lead to increased communication packet loss;
The ground absorbs and reflects radio waves and is less effective when tested close to the ground;
Seawater has a very strong ability to absorb radio waves, so the results of the seaside test are poor;
Signal attenuation can be very severe with metal objects near the antenna, or when placed in a metal case;
The power register is set incorrectly, the air rate is set too high (the higher the air rate, the closer
the distance);
The low voltage of the power supply at room temperature is lower than recommended, the lower the voltage
the lower the transmit power;
Using an antenna that is poorly matched to the module or the quality of the antenna itself.
6.2 Vulnerability of modules
Please check the power supply to ensure that it is between the recommended supply voltages, exceeding the
maximum value can cause permanent damage to the module;
Please check the stability of the power supply, the voltage should not fluctuate significantly and frequently;
Please ensure that the installation and use of the process of anti-static operation, high-frequency devices
electrostatic sensitivity;
Please make sure that the humidity during installation and use is not too high, as some of the components
are humidity sensitive;
It is not recommended to use it at too high or too low a temperature if there is no special need.
6.3 BER too high
There is co-channel signal interference in the vicinity, stay away from the interference source or modify
the frequency or channel to avoid the interference;
An unsatisfactory power supply may also cause garbled code, be sure to ensure the reliability of the power
supply;
Poor quality or too long extension cords and feeder cables can also cause high BER.