03H
Read/
Write
REG0
7 6
5
UART Serial port rate (bps)
For two radios that communicate with
each other, the serial port baud rate can
be different, and the verification method
can also be different;
When continuously transmitting large
data packets, users need to consider the
data congestion caused by the same baud
rate, and may even be lost;
It is generally recommended that the
baud rate of the two communication
parties be the same.
0 0
0
Serial port baud rate1200
0 0
1
Serial port baud rate2400
0 1
0
Serial port baud rate4800
0 1
1
Serial port baud rate9600
(Default)
1 0
0
Serial port baud rate19200
1 0
1
Serial port baud rate38400
1 1
0
Serial port baud rate57600
1 1
1
Serial port baud rate115200
4 3
Serial port check digit
The serial port mode of the two
communication parties can be different;
0 0
8N1(Default)
0 1
8O1
1 0
8E1
1 1
8N1 (equivalent to 00)
2 1
0
Wireless air rate (bps)
The air rate of both parties must be the
same
The higher the air rate, the smaller the
delay and the shorter the transmission
distance.
0 0
0
Air speed0.3k
0 0
1
Air speed1.2k
0 1
0
Air speed2.4k(Default)
0 1
1
Air speed4.8k
1 0
0
Air speed9.6k
1 0
1
Air speed19.2k
1 1
0
Air speed38.4k
1 1
1
Air speed62.5k
04H
Read/
Write
REG1
7 6
Subcontracting settings
The data sent by the user is less than the
sub-packet length, and the serial port
output of the receiving end appears as an
uninterrupted continuous output;
If the data sent by the user is larger than
the packet length, the serial port of the
receiving end will output in packets.
0 0
240byte(Default)
0 1
128byte
1 0
64byte
1 1
32byte
5 RSSI Environmental noise enable
After enabling, you can send commands
C0 C1 C2 C3 in transmission mode or
WOR sending mode to read registers;
Register 0x00: Current environmental
noise RSSI;
Register 0X01: RSSI when receiving
data last time
(The current channel noise is: dBm
=-RSSI/2);
Instruction format: C0 C1 C2 C3 + start
a read length;
Return: C1 + address a read
read valid value; for example:
0 Disabled (default)
1 Enable