Chengdu Ebyte Electronic Technology Co., Ltd.
E810-TTL-CAN01 User Manual
Co
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co., Ltd.
4
1.3 Application
CAN-BUS networks in Industrial control;
Auto and railway equipment networking, on-site network data monitoring;
For existing RS-232 devices to be connected to the CAN-bus network;
Underground remote communication;
Security, fire protection network;
⚫
CAN-bus application systems such as Intelligent building control data broadcasting system;
Parking equipment control;
Smart home.
2. Technical Parameters
2.1 Limit parameter
Main parameter
Performance
Note
Min
Max
Voltage supply
(
V
)
2.3
5.5
Voltage over 5.5V will cause permanent damage to module, 5V
and 3.3V are recommended
Operating temperatur
(
℃
)
-40
+85
Industrial grade
2.2 Operating parameter
Category
Items
Value
UART
Baud rate
115200 bps
Parity
none
Data bit
8
Stop bit
1
Flow Control
off
CAN
CAN baud rate Flow Control
100kbps
CAN ID
0x00000000
Flow Control
off
Default operating mode
Transparent transmission mode
Receive all kinds of data
Default device address
Modbus device address
Default device address is 1
Frame sub-packing
parameter
Time
10ms
Byte
1000byte