OK
Precautions
Needs to be setup before sending data. Do not set the default value
command
character
command
type
command format
response
CRX1DELAY
(
set the
number of
times to send
)
test
command
AT+CRX1DELAY=?
+CRX1DELAY:
“
Delay
”
OK
query
command
AT+CRX1DELAY?
+CRX1DELAY:<Delay>
OK
set
command
AT+CRX1DELAY=<Delay>
OK
Parameter
Description
Delay: how long to open the RX1 window after sending, unit: s;
Return value
description
example
AT+CRX1DELAY=2
OK
Precautions
Set how long to open the RX1 window after sending, set before sending data. It is
the protocol default value when not set.
command
character
command
type
command format
response
CSAVE
(
Save MAC
parameter
settings
)
test
command
AT+CSAVE=?
+CSAVE
OK
set
command
AT+CSAVE
OK
Parameter
Description
<MType>: 0: unconfirm package, 1: confirm package.
<value>: It is the maximum sending times, value range: 1~15;
Return value
description
example
This command saves the configuration parameters to EERPOM/FLASH.
After executing the AT+RESET command, the module will use the new MAC
configuration parameters for network initialization and operation.
Precautions
Need to save before sending data
command
character
command
type
command format
response
CRESTORE
(
restore MAC
default
parameters
)
test
command
AT+CRESTORE=?
+CRESTORE
OK
set
command
AT+CRESTORE
OK
Parameter
Description
This command restores MAC default configuration parameters to
EERPOM/FLASH.