Chengdu Ebyte Electronic Technology Co,;Ltd
E62-433T30D user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co,;Ltd
3
Health care products
;
Advanced Meter Reading Architecture(AMI)
;
Automotive industry applications.
2. Specification and parameter
2.1 2.1 Limit parameter
Main parameter
Performance
Remarks
Min.
Max.
Power supply
(
V
)
0
5.5
Voltage over 5.5V will cause permanent
damage to module
Blocking power
(
dBm
)
-
10
Chances of burn is slim when modules
are used in short distance
Operating temperature
(
℃
)
-40
85
2.2 Operating parameter
Main parameter
Performance
Remark
Min
Typ.
Max.
Operating voltage
(
V
)
3.3
5.0
5.5
≥5.0 V ensures output power
Communication level
(
V
)
3.3
For 5V TTL, it may be at risk of
burning down
Operating temperature
(
℃
)
-40
-
85
Industrial design
Operating frequency
(
MHz
)
425
-
450.5
Support ISM band
Power
consumption
Transmitting current [mA]
640
Instant power consumption
Receiving current [mA]
40
Turn-off current [μA]
-
Software is shut down
Max Tx power
(
dBm
)
29.6
30.0
31.4
Receiving sensitivity
(
dBm
)
-108
-109
-110
Air data rate is 64kbps
Air data rate
(
bps
)
16k
64k
128k
Controlled via user’s programming
Main parameter
Description
Remark
Distance for reference
3000m
Test condition
:
clear and open area, antenna gain: 5dBi
,