background image

SX1276 Wireless Module                                                                                                                                                                User Manual of  E32(915T30S)

 

Series Modules 

Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd.                                                                                                                            10 / 14 

 

Default parameter values:C0 00 00 1A 17 44

 

Model

 

Frequency

 

Address

 

Channel

 

Air data rate

 

Baud rate

 

Parity

 

Transmitting power

 

E32(915T30S) 

915MHz   

0x0000 

0x0F 

2.4kbps 

9600 

8N1 

1W 

4.2 Reading Operating Parameters 

Instruction format 

Description 

C1+C1+C1 

In sleep mode(M0=1,M1=1), 
User gives the module instruction (HEX format): C1 C1 C1, 
Module returns the present configuration parameters.   
For example, C0 00 00 1A 17 44. 

4.3 Reading Version Number 

Instruction format 

Description 

C3+C3+C3 

In sleep mode(M0=1,M1=1), 
User gives the module instruction (HEX format): C3 C3 C3, 
Module returns its present version number, for example C3 44 xx yy. 
44 here means the module model (E44 series); xx is the version number and yy refers to the other module 
features. 

4.4 Reset Instruction 

Instruction format 

Description 

C4+C4+C4 

In sleep mode(M0=1,M1=1), 
User gives the module instruction (HEX format): C4 C4 C4, the module resets for one time. During the reset 
process, the module will conduct self-check, AUX outputs low level. After reset completing, the AUX outputs 
high level, then the module starts to work regularly which the working mode can be switched or be given 
another instruction. 

4.5 Parameter Setting Instruction 

No.

 

Item

 

Description 

 

Remark

 

0

 

HEAD

 

Fix 0xC0 or 0xC2, it means this frame data is control command

 

Must be 0xC0 or 0xC2 
C0: Save the parameters when power-down 
C2:  Do  not  save  the  parameters  when 
power-down

 

1

 

ADDH

 

High address byte of module 

(the default 00H) 

 
00H-FFH

 

2

 

ADDL

 

Low address byte of module 

(the default 00H) 

 
00H-FFH

 

  SPED 

UART parity bit 

 

UART  mode  can  be  different  between 

communication parties

 

8N1(default  ) 

8O1 

8E1 

8N1(equal to 00) 

      TTL UART baud rate(bps) 

 

UART baud rate can be different between 

communication parties 

 

The  UART  baud  rate  has  nothing  to  do 

with wireless transmission parameters & 

won’t  affect  the  wireless  transmit  / 

receive features. 

1200bps 

2400bps 

4800bps 

9600bps(default) 

19200bps 

38400bps 

Содержание E44-TTL-100

Страница 1: ...SX1276 Wireless Module E32 915T30S Series User Manual...

Страница 2: ...ries are applied in open and clear air industrial and living areas with a few obstacles 915M is a North American frequency Mass production has been conducted to export to North American countries Modu...

Страница 3: ...dication of Wireless Transmitting 6 2 6 3 Configuration Procedure of Module 6 2 6 4 Notes for AUX 7 3 Operating Mode 7 3 1 Mode Switch 7 3 2 Normal Mode Mode 0 8 3 3 Wake up Mode Mode 1 8 3 4 Power sa...

Страница 4: ...s 00 01 80 AA BB CC 00 01 refers to the address of module B and 80 refers to the channel of module B Then module B receives AA BB CC only module B Broadcast transmission To set the module address as 0...

Страница 5: ...t the address of module A as 0xFFFF or 0 x0000 and channel as 0x04 When module is the transmitter transparent transmission all modules under channel 0x04 will receive the data the purpose of broadcast...

Страница 6: ...hether all wireless data has been sent through UART or whether the module is still in the process of self check initialization 2 6 1 Indication of UART Output To wake up external MCU 2 6 2 Indication...

Страница 7: ...tion Remark Mode 0 Normal 0 0 UART and wireless channel are open Transparent transmission is on The receiver must work in mode 0 or mode 1 Mode 1 Wake up 1 0 UART and wireless channel are open The dif...

Страница 8: ...iciency of whole system is largely improved 3 2 Normal Mode Mode 0 When M1 0 M0 0 module works in mode 0 Transmitting The module can receive the user data via serial port and transmit wireless data pa...

Страница 9: ...r parameter setting It uses serial port 9600 8N1 to set module working parameters through specific instruction format please refer to parameters setting for details Notes When the mode changes from sl...

Страница 10: ...M0 1 M1 1 User gives the module instruction HEX format C4 C4 C4 the module resets for one time During the reset process the module will conduct self check AUX outputs low level After reset completing...

Страница 11: ...Fixed transmission mode 6 IO drive mode the default 1 This bit is used to the module internal pull up resistor It also increases the level s adaptability in case of open drain But in some cases it may...

Страница 12: ...power must make sure the ability of current output more than 1A and ensure the power supply ripple within 100mV Low power transmission is not recommended due to its low power supply efficiency 0 0 30d...

Страница 13: ...s Due to antenna quality or poor matching between antenna and module 6 2 Module is easy to damage Please check the power supply and ensure it is within the recommended range Voltage higher than the pe...

Страница 14: ...must be installed and operated with a minimum distance of 20 cm between the radiator and user body If the FCC identification number is not visible when the module is installed inside another device th...

Отзывы: