Note
1
、
Connection timeout must be more than connection gap
2
、
Timeout *4 > (1 + latency)* intv;
3
、
Error parameter device will not save
4
、
We do not recommend to change the master connection gap
For example
AT+CONPARAMS=16,0,400
Connection gap 16*1.25ms,slave will delay
:
0
,
16*1.25ms, connection timeout 400*1.25ms
5.4.23 AT+DISCON disconnect command
command
respond
Set
(only for master)
AT+DISCON=[para]
+OK
:
success
+ERR=[NUM]
:
error
Disconnect all
AT+DISCON
+OK
:
success
+ERR=[NUM]
:
error
Parameter
Para (ASCII)
description
0~3
Disconnect all
Remark
1
、
take into effect immediately.
2
、
as slave, only disconnect all is available
;
3
、
Disconnect all is available for master and slave mode
;
4
、
if para specified connection but does not connect, the module will OK.
5.4.24 AT+DATDLY Data output delay
command
respond
Query
AT+DATDLY?
+OK=[para]
Set
AT+DATDLY=[para]
+OK
:
success
+ERR=[NUM]
:
error
Parameter
para
(
ASCII
)
description
0
close
1
enable(default)
Remarks
Take into effect immediately, save when power off
5.4.25 AT+MAC local MAC address
command
respond
Query
AT+MAC?
+OK=[para]
Parameter
para
(
HEX
)
:MAC address