Chengdu Ebyte Electronic Technology Co., Ltd
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co., Ltd
24
Set
:
41 54 2B 42 4F 4E 44 4D 41 43 3D
CC 34 27 1A 0C D4
Return
:
+OK
5.4.29 AT+BONDDEL delete bond MAC address
command
respond
Set
AT+BONDDEL=[mac]
+OK
+ERR=[NUM]
Parameter
mac
:
6bytes mac address
Remarks
1
、
Take into effect immediately, save when power off
2
、
When MAC is (0xff,0xff,0xff,0xff,0xff,0xff
)
delete all MAC address
,
or delate specified mac address
;
5.4.30 AT+SCAN advertising scan
command
respond
Query
AT+SCAN?
+OK=[para]
Set
AT+SCAN=[para]
+OK
:
success
+ERR=[NUM]
:
error
Parameter
para
(
ASCII
)
Description
0
Scan closed
1
Scan enabled(default)
Remarks
1
、
Take into effect immediately, save when power off
2
、
If current connected masters are the maximum, no scanning will be enabled
3
、
Scanning is only available for master and observer
5.4.31 AT+SCANINTV scan interval
command
Respond
Query
AT+SCANINTV?
+OK=[para]
Set
AT+SCANINTV=[para]
+OK
:
success
+ERR=[NUM]
:
error
Parameter
para(ASCII):4~65535
Default: 160
Remarks
1
、
Take into effect immediately, save when power off
2
、
Scanning interval is more than scanning window
3
、
Unavailable for slave, but configuration is ok
For example
AT+SCANINTV=120
Interval
:
120*0.625 = 75ms