Chengdu Ebyte Electronic Technology Co.,Ltd.
E104-BT40 User Manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
4-19
+ERR=[NUM]
:
Error
Parameter
para(ASCII)
Description
0
Off(Default)
1
On
Description
Restart to take effect, save when power off
Example
Turn on flow control
:
AT+HWFC=1
6.4.7 AT+DEVSWVER Software version number
Command
Response
Query
AT+DEVSWVER?
+OK=[para]
Parameter
para(ASCII code):Device software version
Factory default
:
V1.0
6.4.8 AT+SPPNAME SPP Name
Command
Response
Query
AT+SPPNAME?
+OK=[para]
Setting
AT+ SPPNAME =[para]
+ERR=[NUM]
:
Error
Parameter
para(ASCII code):SPP name
Factory default:CDEBYTE_SPP
Description
1. It takes effect after restart or BLE disconnect, save when power off
2. The name length is 1~32 bytes
6.4.9 AT+BLENAME BLE Broadcast name
Command
Response
Query
AT+BLENAME?
+OK=[para]
Setting
AT+ BLENAME =[para]
+ERR=[NUM]
:
Error
Parameter
para(ASCII code):BLE Broadcast name
Factory default:CDEBYTE_BLE
Description
1
、
It takes effect after restart or BLE disconnect, save when power off
2
、
ASCII code length is 1~20 bytes
6.4.10 AT+MAC SPP MAC Address
Command
Response