![Ebyte E103-W02DTU Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/ebyte/e103-w02dtu/e103-w02dtu_user-manual_3828025033.webp)
Chengdu Ebyte Electronic Technology Co.,Ltd.
E103-W02DTU User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
33
Mode>,<Delay>
Delay: the delay time to enter the low-power state after waking
up (2~240S)
Response:
Power mode set OK
Example
:
AT+PM=0,5
Attention:
1. When Power Mode is set to 0, it enters normal power consumption mode.
24
AT+PM=? Query power consumption parameters
AT+PM=?
Parameter Description:
No parameter
Response:
Power Mode:0 Set Delay:5
Example
:
AT+PM=?
25
AT+HTTP set whether to open the web HTTP function (reboot effective)
AT+HTTP=<Switch>
Parameter Description:
Switch: 0 (off) or 1 (on)
Response:
Http status set OK
Example
:
AT+HTTP=1
26
AT+HTTP=? Check whether HTTP function of web page is on or not
AT+HTTP=?
Parameter Description:
No parameter
Response:
Http Status: 1
Example
:
AT+HTTP=?
27
AT+VER=? Query module version
AT+VER=?
Parameter Description:
No parameter
Response:
E103-W02 V1.1
Example
:
AT+VER=?
28
AT+MAC=? Query MAC address
AT+MAC=?
Parameter Description:
No parameter
Response:
MAC address
Example: AT+MAC =?
Return: 7cec79378316
29
AT+ONENETUNI OneNET device login parameters configuration (For OneNET, please refer to
E103-W02 OneNET Cloud Transit User's Guide)
AT+ONENETUNI=<ON/OFF>,P_ID,A_In
fo,S_name
Parameter Description:
ON/OFF: ON(on) OFF(off) If OFF, the following parameters are
invalid (default is OFF)
P_ID: OneNET product ID
A_Info: OneNET device authentication information
S_name: OneNET product script file name
Response:
OneNET Uni Set OK
Example: AT+ONENETUNI=ON,97562,02,ebyte_lua or AT+ONENETUNI=OFF
Return: OneNET Uni Set OK
30
AT+ONENETUNI=? OneNET device login parameters query
AT+ONENETUNI=
?
Parameter Description:
No parameter
Response:
status:ON P_ID:97562 AU_Info:02 S_Name:ebyte_lua
Instance: AT+ONENETUNI=?