background image

 

Publication # 2302-13 

  EBSRAY PUMPS 

 
 

INSTALLATION, OPERATION & 
MAINTENANCE INSTRUCTIONS

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

 
 
 
 
 
 
 
 
 
 
 

 
 

 

 
 
 
 
 

 
 

 

 
 
 

 

V SERIES 

 

MODELS V2000, V3000 & V3010  

 

ROTARY SLIDING VANE PUMPS

 

 

 

 

 

 

 

V3000 

V3010 

V2000 

Содержание V Series

Страница 1: ...Publication 2302 13 EBSRAY PUMPS INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS V SERIES MODELS V2000 V3000 V3010 ROTARY SLIDING VANE PUMPS V3000 V3010 V2000...

Страница 2: ...ment s conformity Failure to comply with the instructions and recommendations contained in this Publication may void CE conformity 3 This Publication does NOT depict a Ancillary required equipment rel...

Страница 3: ...ipment supplied utilises components other than those manufactured by Ebsray e g electrical equipment switches fittings valves etc reference should be made to the original manufacturer s data before in...

Страница 4: ...ve suction resistance 2 5 COUPLING ALIGNMENT To maximise the life of the pump appropriate alignment of the coupled shafts is a fundamental requirement of any coupling installation NOTE Coupling types...

Страница 5: ...ing before checking direction of rotation 3 4 OPERATIONAL CHECKS Inspect pump frequently during the first few hours of operation for such conditions as excessive heating of ball bearings vibration or...

Страница 6: ...age and straightness Replace the pushrods if they show signs of physical damage wear or distortion e g mushroomed rounded or tapered ends scoring on flanks bending etc 4 Inspect vanes for wear or dama...

Страница 7: ...eused as bending the tabs more than once may cause fatigue which could result in failure and or major pump damage Only reassemble with new lockwashers of the correct thickness Refer parts list TO SET...

Страница 8: ...7 Dust Cap Inspection End or Shaft Cap Inspection End 1 640 Dowel 2 400 Valve Cover 1 650 Grease Nipple 2 401 Adjusting Screw Bypass Valve 1 651 Grease Pressure Relief 4 409 Valve 1 Adaptor Flange Opt...

Страница 9: ...9...

Страница 10: ...ve restriction Incorrectly set external Bypass Valve or internal Pressure Relief Valve Valve pressure setting too low Adjust pressure setting but do NOT exceed system design pressure or driver capabil...

Страница 11: ...tandards EN ISO 12100 1 2003 EN ISO 12100 2 2003 EN 809 1998 Manufacturer s own warning Subject to the use for which the product s were designed and or installed in accordance with the relevant Standa...

Страница 12: ...12 NOTES...