EBS-6200
Printer User's Manual
Chapter 4 - Operating the Printer
46
20091020#1.0
Un
You can use a sp
) in order to print current date and time (in various formats)
on objects autom
of month in the current date,
n
B
tens of hours of the current
C
units of hours of the current
J
units of minutes of the curre
T
tens of seconds of the curre
on),
U
units of seconds of the current time (option),
cters available from the terminal keypad rather than with
x$/HZ/20Z$
, if the following assignments
have been made:
0 => Z
,
1 => H
,
2 => x
,
9 => $
.
iversal Date and Time
ecial register (
Univ. date
atically.
Below, there is a list of characters that can be used to encode date and time. Elements of the
universal date
register can be preceded, separated and followed by any characters different from the
specified below.
D
tens of day in the current date,
A
units of day in the current date,
M
tens of month in the current date,
O
units
Y
tens of year in the current date,
E
units of year in the curre t date,
time,
time,
I
tens of minutes of the current time,
nt time,
nt time (opti
NOTE
: During printing, the above mentioned date and time components (D, A, M, O, Y, E, B,
C, I, J, T, U) are replaced with digits (0-9), as standard. It is also possible that an
additional way of coding is used and the above mentioned date and time components
are replaced with any chara
digits. The assignment is made in the submenu
TEXT SERVICE
UNIV.DATE REG. CONFIGURATION DIGIT CODING
. The same characters can be
assigned to different digits. For example, the date of
29/10/2009,
coded as
DA/MO/20YE
, can appear on a overprint as
W
tens of week-of-the-year number,
in the
ate by week-of-the-year number (e.g. if week 53 ends on 5
r of the current date by week-of-the-year number,
anged in the
TION
y-of-the-year number,
S
units of day-of-the-year number,
er of day of the week (1- Monday, 2-Tuesday, ... , 7-Sunday),
h,
d with a single
r of day is
made in the submenu
TEXT SERVICE
UNIV.DATE
REG.
CONFIGURATION
The same characters can be assigned to different hours.
Working shifts identified by numbers
1
,
2
or
3
cover the following time periods as standard:
1
st
shift - from 6:00 to 14:00,
2
nd
shift - from 14:00 to 22:00,
K
tens of week-of-the-year number,
a
number of week of the year coded with one character. The assignment is made
submenus
TEXT SERVICE
UNIV.DATE
REG.
CONFIGURATION
WEEK CODING (1 CHAR)
.
y
tens of year of the current d
th
January next year, then 5
th
January falls within the previous year’s week),
e
units of yea
m
number of month printed with the following encoded letters:
A B C D E F G H L M N P
(corresponding to numbers from 1 to 12, respectively). The assignment can be ch
submenus
TEXT SERVICE
UNIV.DATE
REG.
CONFIGURA
MONTH CODING (1 CHAR)
.
P
hundreds of da
Q
tens of day-of-the-year number,
N
numb
F
the first letter of the month,
G
the second letter of the mont
H
the third letter of the month,
b
the number (between 0 and 23) of the hour of day of current time code
character.
The assignment of any character available via the terminal keypad to each hou
HOUR CODING (1 CHAR)
.
Z
working shift identifier,
3
rd
shift - from 22:00 to 6:00, on every day of the week.
Содержание EBS-6200
Страница 1: ...EBS 6200 USER S MANUAL Ink Jet technology for the future...
Страница 2: ......