The thermometer is a non-contact infrared thermometer, and always with Real-Time Maximum (MAX) data.   
Please remember to keep away from children and don’t use it for safety related applications. 
 

           

 

 

(Default Screen) 

 

 

ADD VALUE: 

o

C or 

o

Press Mode key (

,

2

) for 

o

C or 

o

F transferred. 

Backlight

 

LCD Backlight: always on. 

Laser

 

Class II Laser: always enable while measuring. 

                The device complies with the following guideline: 

EMC-Guideline 2004/108/EC 

 

Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 
3 volts per meter, but the performance of the instrument will not be permanently affected. 

* Note: Under the electromagnetic field of 3V/m from 350 to 550MHZ, the maximum error is 8°C (14.4°F). 

 

 

ebro Electronic GmbH & Co. KG    http://www.ebro.com 

Peringerstrasse 10, 85055 Ingolstadt   

GERMANY. 

 

 

CAUTION 

1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE MAY RESULT. 

2. USE EXTREME CAUTION WHEN OPERATING THE LASER. 

3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.   

4. KEEP OUT OF REACH OF ALL CHILDREN. 
STORAGE & CLEANING 

The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times, care should be taken when 
cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allowing the lens to fully dry before using the 
thermometer. Do not submerge any part of the thermometer. The thermometer should be stored at room temperature between –20 to 
+65°C (-4~149°F).

 

LCD ERROR MESSAGES 

The thermometer incorporates visual diagnostic messages as follows: 

 

 

‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature.   
 
‘Er3’ is displayed when the ambient temperature exceeds 0

o

C(32°F) or +50

o

C (122°F).   

The  thermometer  should  be  allowed  plenty  of  time  (minimum  30  minutes)  to  stabilize  to  the  working/room 
temperature. 

 

Error 5~9

, for all other error messages it is necessary to reset the thermometer. To reset it, turn the instrument 

off,  remove  the  battery  and  wait  for  a  minimum  of  one minute,  reinsert  the  battery  and  turn  on.  If  the  error 
message remains please contact the Service Department for further assistance. 

 

 

‘Hi’ or ’Lo’ is displayed when the temperature being measured is outside of the measurement range. 

BATTERIES

 

The thermometer incorporates visual low battery indication as follows: 

 

 

 

‘Battery OK’: measurements 

  are possible 

‘Battery Low’: battery needs to be   

replaced, measurements are still possible 

‘Battery Exhausted’: measurements are 

not possible 

  When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AAA, 1.5V batteries. 

Please note: It is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction. 
Dispose of used battery promptly and keep away from children. 

SPECIFICATION 

Measurement Range 

-35 to +365

 o

C (-31 to +689

 o

F) 

Operating Range 

0~50°C (32~122°F) 

Accuracy, (Tobj=15-35°C,Tamb=25°C) 

+/-1.5°C (2.7°F) 

Accuracy (Tamb=23 +/- 3°C) 

Tobj=0~365°C:+/-2.5% of reading or 2.5°C (4.5°F) whichever is greater 
Tobj=-35~0

 o

C: +/-(2.5°C+0.05/degree) 

Emissivity 

0.95 fixed 

Resolution (-9.9~199.9°C) 

0.2°C/0.5°F and 1°C / 2°F for the remaining 

Response Time (90%) 

1sec 

Distance:Spot 

8:1 

Battery Life 

Typ.18, min 14 hours continuous use 

Dimensions 

166.4 x 33.9 x 63.5mm(6.55×1.33×2.50 inch) 

Weight 

113 grams(3.98 oz) including batteries (AAA*2pcs) 

Protection class 

IP 20 

Wave length 

8… 14µ m 

** The thermometer will automatically shut off if left idle for more than 15sec. 

 

 

1. Simply aim the thermometer at the measure target with Lens (

,

4

) and press 

Meas. key (

,

6

) to display the surface temperature.     

 

2. During the measurement, the MAX reading will be displayed beside the 

 

icon. 

 

3. The Distance:Spot is 8:1. Please make sure the target area is within the field   

of view.

 

Отзывы: