Receiver - Wall-Mounted Appliance Module
Ref : RMA
July 2009
page 6
RMA
Schematic 1
To connect the in-wall switch
.
CONNECTING BLOCK
To learn one address on wall switch (unique
addressable control)
An address is made of a HOUSE code and UNIT code, please refer
to the manual
of the transmitter to properly fix the code to learn
by the receiver.
The following procedure consists of learning one (or even more
than one) address from the transmitter into the RMA receiver.
Pls bear in mind to shut off general mains in the
electrical panel.
Connect all wires as indicated (refer to
wiring diagram 1)
L
: stands for input Live 230V - 50 Hz
N
: stands for input Neutral 230V - 50Hz
How to connect Live + Neutral Input
N
: Neutral
Wiring up Live +
Neutral outputs
: Output Live appliance or light to control
C
:
(do not connect, only
for low voltage)
How to instal wall mount switch
.
Wall insert box : dia. 65mm, 40mm deep
1.Gently take off paddle from wall switch.
2.Wire up Wall Switch within wall insert box, then
fix receiver along with provided screws against wall
insert box.
Up to 10 Amps
Ph
N
Please note that the general mains in the electrical panel
should be turned on again before you start programming.