3.2 Nominal data
Motor
M6D110-IA
Phase
3~
3~
3~
3~
Nominal voltage / VAC
400
400
400
400
Wiring
Δ
Y
Δ
Y
Frequency / Hz
50
50
60
60
Method of obtaining
data
fa
fa
fa
fa
Valid for approval/
standard
CE
CE
CE
CE
Speed (rpm) / min
-1
925
775
1035
730
Power consumption / W
575
420
845
505
Current draw / A
1.45
0.75
1.6
0.95
Max. back pressure / Pa
85
55
50
20
Min. ambient
temperature / °C
-40
-40
-40
-40
Max. ambient
temperature / °C
65
65
40
40
Starting current / A
5.2
1.75
4.8
1.6
Phase
3~
3~
Nominal voltage / VAC
480
480
Wiring
Δ
Y
Frequency / Hz
60
60
Method of obtaining
data
fa
fa
Valid for approval/
standard
CE
CE
Speed (rpm) / min
-1
1090
850
Power consumption / W
925
635
Current draw / A
1.65
0.95
Max. back pressure / Pa
55
30
Min. ambient
temperature / °C
-40
-40
Max. ambient
temperature / °C
40
40
Starting current / A
6
2
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Data according to Commission Regulation (EU) 327/
2011
Actual
Req. 2015
01 Overall efficiency η
es
/ %
34.4
32.6
02 Measurement category
A
03 Efficiency category
Static
04 Efficiency grade N
41.8
40
05 Variable speed drive
No
06 Year of manufacture
The year of manufacture is specified on the
product's rating label.
07 Manufacturer
ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart ·
HRA 590344
D-74673 Mulfingen
08 Type
W6D630-CA01-80
09 Power consumption P
e
/ kW
0.67
09 Air flow q
v
/ m³/h
8655
09 Pressure increase total p
sf
/
Pa
97
10 Speed (rpm) n / min
-1
915
11 Specific ratio
*
1.00
12 Recycling/disposal
Information on recycling and disposal is
provided in the operating instructions.
13 Maintenance
Information on installation, operation and
maintenance is provided in the operating
instructions.
14 Additional components
Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller
combination in a standardized measurement setup.
3.4 Technical description
Weight
25.6 kg
Size
630 mm
Motor size
110
Rotor surface
Painted black
Terminal box material
Die-cast aluminum, painted black
Blade material
Sheet aluminum, painted black
Fan housing material
Sheet steel, galvanized and coated with
white aluminum plastic (RAL 9006)
Guard grille material
Steel, coated with white-aluminum plastic
(RAL 9006)
Number of blades
5
Blade pitch
0°
Airflow direction
A
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP55
Insulation class
"F"
Moisture (F) /
Environmental (H)
protection class
H2+T
Ambient temperature
note
Occasional start-up at temperatures
between -40°C and -25°C is permitted.
For continuous operation at ambient
temperatures below -25°C (such as
refrigeration applications), use must be
made of a fan design with special low-
temperature bearings.
Installation position
Shaft horizontal or rotor on top; rotor on
bottom on request
Condensation
drainage holes
On stator side
Mode
S1
Motor bearing
Ball bearing
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
<= 3.5 mA
Electrical hookup
Terminal box
Motor protection
Thermal overload protector (TOP) with
basic insulation
with cable
Axial
Item no. 13594-5-9970 · ENU · Change 223034 · Approved 2020-10-26 · Page 5 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com