Operating instructions

W4D500-KJ03-01

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Airflow direction "V"

2

Cable silicone 6G 0.5 mm²
6x wire-end ferrule

Item no. 15825-5-9970 · ENU · Change 230069 · Approved 2021-05-19 · Page 4 / 13

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W4D500-KJ03-01

Страница 1: ...zed technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety...

Страница 2: ...he fan to be able to get past the fan 1 6 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accidenta...

Страница 3: ...g the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe v...

Страница 4: ...duct drawing All dimensions in mm 1 Airflow direction V 2 Cable silicone 6G 0 5 mm 6x wire end ferrule Item no 15825 5 9970 ENU Change 230069 Approved 2021 05 19 Page 4 13 ebm papst Mulfingen GmbH Co...

Страница 5: ...ort struts only in X position as illustrated or rotor on bottom 2 For horizontal shaft installation position the cable exit must be at the bottom right Item no 15825 5 9970 ENU Change 230069 Approved...

Страница 6: ...vanes PP plastic Guard grille material Steel coated with black plastic RAL 9005 Number of blades 5 Airflow direction V Direction of rotation Counterclockwise viewed toward rotor Degree of protection...

Страница 7: ...l box kit provides an ideal means of connecting the electrical connections of the motor heating tape and drip pan The terminal box kit to suit the AxiCool fan housing and motor is available from ebm p...

Страница 8: ...vice voltage Only use cables designed for the current level indicated on the nameplate For determining the cross section note the sizing criteria according to EN 61800 5 1 The protective earth must ha...

Страница 9: ...stalled in the winding The motor is provided with a thermal overload protector TOP Always check that the thermal overload protector TOP is properly connected before start up Failure to connect the the...

Страница 10: ...nge of rotation direction by reversing two phases Delta connection L1 blue L2 black L3 brown TW Thermal overload protector gray 2x PE green yellow Item no 15825 5 9970 ENU Change 230069 Approved 2021...

Страница 11: ...switch When disconnecting be sure to disconnect the ground connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm paps...

Страница 12: ...e 5 2 Safety inspection What to check How to check How often What action Contact protection cover for intactness or damage Visual inspection At least every 6 months Repair or replacement of device Dev...

Страница 13: ...xternal rotor motors from ebm papst Mulfingen GmbH Co KG Ferrite magnets can be disposed of in the same way as normal iron and steel Electrical insulating materials on the product in cables and wires...