Operating instructions

W3G630-KL06-G1

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Airflow direction "V"

2

Cable PVC AWG22, 5x crimped ferrules

3

Cable PVC AWG18, 5x crimped ferrules

4

Mounting holes for FlowGrid

Item no. 55310-5-9970 · ENU · Change 222314 · Approved 2021-02-01 · Page 4 / 13

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W3G630-KL06-G1

Страница 1: ...install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazards associated with the device must be ass...

Страница 2: ...appropriate shielding measures have to be taken by the user NOTE Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compl...

Страница 3: ...ctions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation...

Страница 4: ...mm 1 Airflow direction V 2 Cable PVC AWG22 5x crimped ferrules 3 Cable PVC AWG18 5x crimped ferrules 4 Mounting holes for FlowGrid Item no 55310 5 9970 ENU Change 222314 Approved 2021 02 01 Page 4 13...

Страница 5: ...ort struts only in X position as illustrated or rotor on bottom 2 For horizontal shaft installation position the cable exit must be at the bottom right Item no 55310 5 9970 ENU Change 222314 Approved...

Страница 6: ...surement setup 3 4 Technical description Weight 12 5 kg Size 630 mm Motor size 84 Rotor surface Painted black Electronics housing material Die cast aluminum painted black Blade material Press fitted s...

Страница 7: ...om ebm papst under the following item number Size Item no 630 mm 00630 2 7680 During assembly comply with the installation instructions included with each ebm papst heating tape ebm papst assumes no l...

Страница 8: ...ion concerned 4 2 Electrical connection DANGER Voltage on the device Electric shock Always connect a protective earth first Check the protective earth DANGER Faulty insulation Risk of fatal injury fro...

Страница 9: ...sulation of the alarm relay As the alarm relay only has basic insulation for TN TT systems or functional insulation for phase conductor grounded networks with respect to the supply voltage and not dou...

Страница 10: ...rating 250 VAC 2 A AC1 min 10 mA basic insulation on supply side and reinforced insulation on control interface side 2 8 0 10 V yellow Analog input set value SELV 0 10 V Ri 100 k adjustable curve 2 9...

Страница 11: ...and resultant imbalance or be caused by component or structural resonance Speed ranges with excessively high vibration levels and possibly resonant frequencies must be determined in the course of fan...

Страница 12: ...ocate and rectify cause of error release restart lockout if necessary Ambient temperature too high Reduce the ambient temperature Reset by reducing control input to 0 Impermissible point of operation...

Страница 13: ...the applicable country specific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disposal standards are also to be...