Operating instructions
W3G200-HD01-01
Translation of the original operating instructions
(RCCB) with a trip threshold of 300 mA and delayed tripping
(super-resistant, characteristic K).
4.2.4 Locked-rotor protection
Due to the locked-rotor protection, the starting current (LRA) is
equal to or less than the nominal current (FLA).
4.3 Connection via terminal strip
4.3.1 Connecting wires to terminals
WARNING
Live terminals and connections even with device
switched off
Electric shock
→ Wait five minutes after disconnecting the voltage at all poles
before opening the device.
;
Insert the wires into the terminals, see
Chapter 4.5 Connection diagram.
4.4 Connecting the cables
The device has external leads.
;
First connect the "PE" (protective earth).
●
Connect the cables according to your application. When doing so,
observe Chapter 4.5 Connection diagram.
Item no. 51848-5-9970 · ENU · Change 232994 · Approved 2021-05-21 · Page 7 / 11