4.4 Connection screen

No.

Conn.

Designation

Colour

Function / assignment

1

1

Un +48 VDC

red

Power supply 48 VDC, residual ripple 3.5 %

1

2

0-10 VDC

yellow

Control input Re > 100 K

1

3

Tach

white

Speed monitoring output, 3 pulses per rotation, Isink max = 10 mA

1

4

GND

blue

Reference mass

Item no. 51090-5-9970 · ENG · Revision 83494 · Release 2014-09-25 · Page 7 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W1G208-BA73-12

Страница 1: ...ical staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules An...

Страница 2: ...it until all parts have come to a standstill WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear...

Страница 3: ...in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving h...

Страница 4: ...of air flow V 2 Connector housing Molex 39 01 2040 connection line AWG20 with 4x connector socket Molex 39 00 0059 2 1 red 2 2 Control input yellow 2 3 blue 2 4 S white Item no 51090 5 9970 ENG Revisi...

Страница 5: ...lectrical leads With plug Motor protection Reverse polarity and locked rotor protection Cable exit Lateral Product conforming to standard EN 60950 1 Approval UL 1004 1 CSA C22 2 Nr 77 For cyclic speed...

Страница 6: ...y environment Operate the device with a safely isolated power pack 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data Before connecting the device ensure that...

Страница 7: ...supply 48 VDC residual ripple 3 5 1 2 0 10 VDC yellow Control input Re 100 K 1 3 Tach white Speed monitoring output 3 pulses per rotation Isink max 10 mA 1 4 GND blue Reference mass Item no 51090 5 9...

Страница 8: ...he supply voltage 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Return the device to ebm papst for repair or replacement WARNING Terminals and conne...

Страница 9: ...ses or solvents Do not use any pointed or sharp edged objects to clean 5 2 Safety test What has to be tested How to test Frequency Which measure Check the protective casing against accidental contact...