2. PROPER USE

The device is exclusively designed as a built-in device for moving air
according to its technical data.
Any other or secondary use is deemed improper and constitutes a
misuse of the device.
Installations on the customer's side must meet the mechanical, thermal
and service life-related stresses that can occur.

Proper use also includes:

Moving air with a density of 1.2 kg/m³.

Using the device in accordance with the permitted ambient
temperature, see chapter 3.5 Transport and storage conditions and
chapter 3.2 Nominal data.

Operating the device with all protective features in place.

Minding the operating instructions.

Improper use

Using the device in the following ways is particularly prohibited and
may cause hazards:

Operating the device with an imbalance, e.g. caused by dirt deposits
or icing.

Moving air that contains abrasive particles.

Moving highly corrosive air, e.g. salt spray mist. Exceptions are
devices that are intended for salt spray mist and protected accordingly.

Moving air that contains dust pollution, e.g. suctioning off saw dust.

Operating the device close to flammable materials or components.

Operating the device in an explosive atmosphere.

Using the device as a safety component or for taking on safety-
related functions.

Operation with completely or partially disassembled or modified
protective features.

In addition, all application options that are not listed under proper use.

Item no.: 51080-5-9970 · Revision: 71954 · Print-out: 2012-02-24 · Y. Uhlmann (VM-TDO) · Page 3 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W1G115-AG03-07

Страница 1: ...ialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming...

Страница 2: ...come to a standstill WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose clothing or je...

Страница 3: ...lowing ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highly corro...

Страница 4: ...mm 1 Direction of air flow V 2 Connector housing Molex No 50 57 9403 with 3 x female connectors Molex No 16 02 0087 2 1 red 2 2 blue 2 3 white s Item no 51080 5 9970 Revision 71954 Print out 2012 02...

Страница 5: ...tput Motor current limit Soft start Electrical leads With plug Motor protection Reverse polarity and locked rotor protection Cable exit Lateral Product conforming to standard EN 60950 1 For cyclic spe...

Страница 6: ...nly use cables designed for current according to the type plate For determining the cross section follow the basic principles in accordance with EN 61800 5 1 The protective earth must have a cross sec...

Страница 7: ...operating instructions 4 5 Connection diagram Item no 51080 5 9970 Revision 71954 Print out 2012 02 24 Y Uhlmann VM TDO Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 7...

Страница 8: ...ltage at all poles before opening the device CAUTION If control voltage is applied or a speed setpoint is stored the motor automatically restarts e g after a power failure Danger of injury Keep out of...

Страница 9: ...asure Check the protective casing against accidental contact for damage and to ensure that it is intact Visual inspection At least every 6 months Repair or replacement of the device Check the device f...