FAULTS, POSSIBLE CAUSES AND REMEDIES

 

 
Replace your product by a new one, do not repair it. 
 

 

DANGER 

Electrical voltage at motor 
 

 

Wait five minutes after the voltage 
(all poles) has been switched off 
before opening the product. 

 
 
Fault/  
Error 

Possible cause 

Possible remedial 
action 

Mechanical 
blocking 

Switch off, de-energize 
and eliminate 
mechanical blocking. 

Mains voltage fault  Check mains voltage, 

re-connect voltage 
supply. 

Connection faulty 

Rectify connection, see 
pin connection. 

Motor is too hot 

Allow motor to cool / 
identify cause of fault. 

Motor winding 
interrupted 

Exchange product.  

Motor is not 
rotating 

Ambient 
temperature too 
high 

Reduce ambient 
temperature if possible. 

Impeller out of 
true 

Unbalance of 
rotating parts 

Clean product if still 
unbalanced after 
cleaning, exchange 
product. 

 

 

Note 
 
If the device is not operated for a 
lengthy period in installed condition in a 
dry environment, it is to be started up 
and operated at full speed for one hour 
at least every four months. If the device 
is not operated for a lengthy period in 
installed condition in a damp 
environment (e.g. outdoors), it is to be 
started up and operated at full speed 
for at least three hours once a month to 
move the bearings and allow any 
condensate that may have ingressed to 
evaporate. 
 
In case of further faults, contact ebm-
papst. 

 
Technical safety inspection 
 
What requires checking? 

How to 
check? 

Frequency 

Protection against accidental 
contact/ protective clothing 

Visual 
inspection 

min. 1/2 
yearly 

Check product for damage 

Visual 
inspection 

min. 1/2 
yearly 

Fixation of product 

Visual 
inspection 

min. 1/2 
yearly 

Fixation of wires 

Visual 
inspection 

min. 1/2 
yearly 

Insulation of wires 

Visual 
inspection 

min. 1/2 
yearly 

Check impeller for 
wear/sediments/ corrosion 

Visual 
inspection 

min. 1/2 
yearly 

 
 

 

Содержание RV45-3/14

Страница 1: ...es The following risk ratings are used in this operating manual to denote potential risk situations and important safety instructions DANGER This is a potentially dangerous situation and warns of an impending health risk or risk of fatal injury if this warning is not observed Observe this warning WARNING The dangerous situation can occur and can result in major or fatal injuries if the warning is ...

Страница 2: ...ransported by the airflow The product can transport small parts in the airflow and catapult them out Ensure that there are no loose small parts in the intake and exhaust area Do not stand in the danger zone of the product CAUTION High risk of fire spreading Can cause fire to spread Never direct the airflow intake exhaust side at a potential source of fire Hot surface CAUTION High temperature at mo...

Страница 3: ...ceed the permissible vibration load Operating the product close to inflammable materials or components Operating the product in an explosive atmosphere Use of the prouct as a safety component or for performing safety relevant functions Operating in medical devices with life sustaining or life saving function if not validated together with ebm papst Operating in non stationary systems e g railway v...

Страница 4: ...ctly exposure to water must be avoided Pollution degree 1 according DIN EN 60664 1 There is either no pollution or it occurs only dry non conductive pollution The pollution has no negative impact Ambient conditions Permitted ambient temperature Transport and storage Operation 40 C 85 C 20 C 70 C Vibration and shock load The mechanical Vibration and Shock data for the product is available If the op...

Страница 5: ...ch the product is installed against switching on again NOTE Electromagnetic compatibility EMC may affect the system integration of the product due to interaction Ensure the electromagnetic compatibility of the entire system Voltage control Speed control via the supply voltage is only permitted within the stipulated supply voltage range Speed control via PWM of the supply voltage is not permitted R...

Страница 6: ...ge product Note If the device is not operated for a lengthy period in installed condition in a dry environment it is to be started up and operated at full speed for one hour at least every four months If the device is not operated for a lengthy period in installed condition in a damp environment e g outdoors it is to be started up and operated at full speed for at least three hours once a month to...

Страница 7: ......

Отзывы: