background image

 

 

page 4 of 7 

 

TECHNICAL DATA

 

 
Drawing, see annex 
 
Technical description 
 
Airflow direction 

Air in axially, Air out radially 

Rotating direction looking 
at rotor 

Counterclockwise 

Nominal voltage 

24 V

 

Current consumption 

1.750 mA

 

Power consumption 

42 W

 

Speed 

39.200 1/min

 

Max. free-air flow 

438 l/min 

Mass 

0,13 kg 

Protection class 

 

 
The product is intended for use in sheltered rooms with controlled 
temperature and controlled humidity. Directly exposure to water must 
be avoided. 
 
Pollution degree 1 (according DIN EN 60664-1) 
There is either no pollution or it occurs only dry, non-conductive 
pollution. The pollution has no negative impact. 
 
 
 
Ambient conditions 
 
Permitted ambient temperature 
Transport and storage 

Operation 

-40 °C ... 85 °C 

-20 °C ... 70 °C 

 
Vibration and shock load 
 
The mechanical Vibration and Shock data for the product is available. 
If the operation of the product should take place in a sinusoidal 
vibration containing environment or fixing the product on sinusoidal 
vibrating surface, please contact our technical support. 
 
Do not operate your product in the resonance range. 

Содержание RV45-3/14

Страница 1: ...es The following risk ratings are used in this operating manual to denote potential risk situations and important safety instructions DANGER This is a potentially dangerous situation and warns of an impending health risk or risk of fatal injury if this warning is not observed Observe this warning WARNING The dangerous situation can occur and can result in major or fatal injuries if the warning is ...

Страница 2: ...ransported by the airflow The product can transport small parts in the airflow and catapult them out Ensure that there are no loose small parts in the intake and exhaust area Do not stand in the danger zone of the product CAUTION High risk of fire spreading Can cause fire to spread Never direct the airflow intake exhaust side at a potential source of fire Hot surface CAUTION High temperature at mo...

Страница 3: ...ceed the permissible vibration load Operating the product close to inflammable materials or components Operating the product in an explosive atmosphere Use of the prouct as a safety component or for performing safety relevant functions Operating in medical devices with life sustaining or life saving function if not validated together with ebm papst Operating in non stationary systems e g railway v...

Страница 4: ...ctly exposure to water must be avoided Pollution degree 1 according DIN EN 60664 1 There is either no pollution or it occurs only dry non conductive pollution The pollution has no negative impact Ambient conditions Permitted ambient temperature Transport and storage Operation 40 C 85 C 20 C 70 C Vibration and shock load The mechanical Vibration and Shock data for the product is available If the op...

Страница 5: ...ch the product is installed against switching on again NOTE Electromagnetic compatibility EMC may affect the system integration of the product due to interaction Ensure the electromagnetic compatibility of the entire system Voltage control Speed control via the supply voltage is only permitted within the stipulated supply voltage range Speed control via PWM of the supply voltage is not permitted R...

Страница 6: ...ge product Note If the device is not operated for a lengthy period in installed condition in a dry environment it is to be started up and operated at full speed for one hour at least every four months If the device is not operated for a lengthy period in installed condition in a damp environment e g outdoors it is to be started up and operated at full speed for at least three hours once a month to...

Страница 7: ......

Отзывы: