ebm-papst R2S175-AA07-39 Скачать руководство пользователя страница 5

Operating instructions

R2S175-AA07-39

Translation of the original operating instructions

3.2 Nominal data

Motor

M2S052-CA

Phase

1~

Nominal voltage / VAC

230

Frequency / Hz

50

Type of data definition

fa

Valid for approval /
standard

CE

Speed / min

-1

2600

Power input / W

75

Current draw / A

0.5

Min. back pressure / Pa

0

Max. ambient
temperature / °C

40

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Technical features

Mass

0.9 kg

Size

175 mm

Surface of rotor

Uncoated

Material of impeller

PA plastic 6, fibreglass-reinforced

Number of blades

7

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 20

Insulation class

"F"

Mounting position

Any

Condensate discharge
holes

None, open rotor

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

Approval

CCC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 10622-5-9970 · Revision 68158 · Release 2010-11-10 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R2S175-AA07-39

Страница 1: ...un and work on the electrical system Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Bas...

Страница 2: ...could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNI...

Страница 3: ...the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highl...

Страница 4: ...5 mm 3x receptacles for tabs 6 3 x 0 8 crimped 1 1 PE 1 2 L 1 3 N 2 Accessory part Inlet nozzle 09576 2 4013 not included in the standard scope of delivery 3 Depth of screw max 5 mm Item no 10622 5 99...

Страница 5: ...k Fig 4 TN system 0 75 mA Motor protection Thermal overload protector TOP wired internally Protection class I if protective earth is connected by customer Product conforming to standard EN 60335 1 CE...

Страница 6: ...wires Water enters at the cable end on the customers side and can damage the device Make sure that the cable end is connected in a dry environment Connect the device only to circuits that can be switc...

Страница 7: ...4 3 Connection screen L blue PE green yellow N brown TOP Thermal overload protector Item no 10622 5 9970 Revision 68158 Release 2010 11 10 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 M...

Страница 8: ...after a power failure Danger of injury Keep out of the danger zone of the device When working on the device switch off the mains supply voltage and secure the latter from being switched on again Wait...

Страница 9: ...l inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of protective earth connection Visual inspection...

Отзывы: