ebm-papst R2S175-AA07-39 Скачать руководство пользователя страница 4

Operating instructions

R2S175-AA07-39

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All measures have the unit mm.

1

Connection line silicone 3G 0.5 mm², 3x receptacles for tabs 6.3 x 0.8, crimped

1.1

PE

1.2

L

1.3

N

2

Accessory part: Inlet nozzle 09576-2-4013, not included in the standard scope of delivery

3

Depth of screw max. 5 mm

Item no. 10622-5-9970 · Revision 68158 · Release 2010-11-10 · Page 4 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R2S175-AA07-39

Страница 1: ...un and work on the electrical system Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Bas...

Страница 2: ...could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNI...

Страница 3: ...the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highl...

Страница 4: ...5 mm 3x receptacles for tabs 6 3 x 0 8 crimped 1 1 PE 1 2 L 1 3 N 2 Accessory part Inlet nozzle 09576 2 4013 not included in the standard scope of delivery 3 Depth of screw max 5 mm Item no 10622 5 99...

Страница 5: ...k Fig 4 TN system 0 75 mA Motor protection Thermal overload protector TOP wired internally Protection class I if protective earth is connected by customer Product conforming to standard EN 60335 1 CE...

Страница 6: ...wires Water enters at the cable end on the customers side and can damage the device Make sure that the cable end is connected in a dry environment Connect the device only to circuits that can be switc...

Страница 7: ...4 3 Connection screen L blue PE green yellow N brown TOP Thermal overload protector Item no 10622 5 9970 Revision 68158 Release 2010 11 10 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 M...

Страница 8: ...after a power failure Danger of injury Keep out of the danger zone of the device When working on the device switch off the mains supply voltage and secure the latter from being switched on again Wait...

Страница 9: ...l inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of protective earth connection Visual inspection...