background image

Operating instructions

R2E250-RA50-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M2E068-EC

Phase

1~

1~

Nominal voltage in VAC

230

230

Frequency in Hz

50

60

Type of data definition

ml

ml

Valid for approval /
standard

CE

CE

Speed in min

-1

2500

2450

Power input in W

210

285

Current draw in A

0.93

1.25

Motor capacitor in µF

5

5

Capacitor voltage in VDB

400

400

Capacitor standard

P0 (CE)

P0 (CE)

Min. back pressure in Pa

0

0

Min. ambient
temperature in °C

-25

-25

Max. ambient
temperature in °C

70

50

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Data acc. to ErP Directive

Installation category

A

Efficiency category

Static

Variable speed drive integrated

No

Specific ratio

*

1,00

*

Specific ratio = 1 + p

sf

/ 100 000

Actual

Request
2013

Request
2015

Overall efficiency η

e

40,6

40,4

44,4

Efficiency grade N

58,2

58

62

Power input P

e

in kW

0,21

Air flow q

v

in m³/h

905

Pressure increase total p

sf

in Pa

334

Speed n in min

-1

2505

Data established at point of optimum efficiency

3.4 Technical description

Size

250 mm

Surface of rotor

Coated in black

Material of impeller

Plastic PA6, fibreglass-reinforced

Number of blades

7

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position

Insulation class

"F"

Humidity class

F1-2

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Leakage current

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Graphic rendition of products

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no.: 11455-5-9970 · Revision: 75902 · Print-out: 2012-02-20 · Y. Uhlmann (VM-TDO) · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R2E250-RA50-01

Страница 1: ... and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re evaluated once it is installed in the end device Observe the following when working on the unit Do not make any modifications additions or conversions to...

Страница 2: ...e entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNING Depending on the installation and operating conditions a sound pressure level greater than 70 dB A may arise Danger of noise induced hearing loss Take appropriate technical safety measures Protect operating p...

Страница 3: ...llowing ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highly corrosive air e g salt spray mist Exceptions are devices that are intended for salt spray mist and protected accordingly Moving air that contains dust pollution e g suctioning off saw dust Operating the d...

Страница 4: ...ne silicone 4G 0 5 mm 4 x brass lead tips crimped 2 Accessory part Inlet nozzle 96359 2 4013 not included in the standard scope of delivery 3 Depth of screw max 6 mm Item no 11455 5 9970 Revision 75902 Print out 2012 02 20 Y Uhlmann VM TDO Page 4 9 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 7938 81 0 Fax 49 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 5: ...Number of blades 7 Direction of rotation Clockwise seen on rotor Type of protection IP 44 Depending on installation and position Insulation class F Humidity class F1 2 Mounting position Any Condensate discharge holes None Operation mode S1 Motor bearing Ball bearing Leakage current 0 75 mA Motor protection Thermal overload protector TOP wired internally Cable exit Variable Protection class I if pr...

Страница 6: ...vironment Connect the device only to circuits that can be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data and the data of the operating capacitor Before connecting the device ensure that the supply voltage matches the operating voltage of the device Only use cables designed for current according to the ...

Страница 7: ...ns 4 4 Connection diagram U1 blue Z brown U2 black PE green yellow Item no 11455 5 9970 Revision 75902 Print out 2012 02 20 Y Uhlmann VM TDO Page 7 9 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 7938 81 0 Fax 49 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 8: ...ctric shock risk of injury Discharge the capacitors before working on the device CAUTION The motor restarts automatically when operating voltage is applied e g after a power failure Danger of injury Keep out of the danger zone of the device When working on the device switch off the mains supply voltage and secure the latter from being switched on again Wait until the device stops If the device rem...

Страница 9: ...r replacement of the device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of protective earth connection Visual inspection At least every 6 months Fasten Check the insulation of the wires for damage Visual inspection At least every 6 months...

Отзывы: