background image

Operating instructions

R1G225-AF11-14

Translation of the original operating instructions

3.2 Nominal data

Motor

M1G074-BF

Nominal voltage / VDC

48

Nominal voltage
range / VDC

36 .. 57

Frequency / Hz

-

Method of obtaining
data

fa

Speed (rpm) / min

-1

2700

Power consumption / W

95

Current draw / A

2.2

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

60

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

1.6 kg

Size

225 mm

Motor size

74

Rotor surface

Painted black

Impeller material

PA plastic

Number of blades

7

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP44

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H2

Installation position

Any

Condensation
drainage holes

None

Mode

S1

Motor bearing

Ball bearing

Technical features

- Tach output
- Motor current limitation
- Soft start
- PWM control input

Electrical hookup

Connector with cable

Motor protection

Reverse polarity and locked-rotor
protection

with cable

Variable

Conformity with
standards

EN 60950-1

Approval

UL 1004-1; CSA C22.2 No. 77

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.

3.4 Mounting data

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

For screw clearance, see Chapter 3.1 Product drawing

Strength class of
screws

8.8

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

-40 °C

3.6 Electromagnetic compatibility

EMC immunity to
interference

According to EN 61000-6-2 (industrial
environment)

EMC interference
emission

According to EN 55022 (Class B,
household environment)

Item no. 53155-5-9970 · ENU · Change 202598 · Approved 2020-01-07 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R1G225-AF11-14

Страница 1: ...authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic...

Страница 2: ...tact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and...

Страница 3: ...hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan...

Страница 4: ...ed in scope of delivery 2 Max clearance for screw 6 mm 3 Cable PVC AWG20 with 4 pole connector housing AMP 207571 1 3 1 UN 48 VDC red 3 2 GND blue 3 3 PWM black 3 4 Fan good fan bad white Item no 5315...

Страница 5: ...e in accordance with its degree of protection Information on surface quality The surfaces of the products conform to the generally applicable industrial standard The surface quality may change during...

Страница 6: ...ecting switch Only connect the fan to circuits that can be switched off with an all pole disconnection switch When working on the fan secure the system machine in which the fan is installed so as to p...

Страница 7: ...y 48 VDC maximum ripple 3 5 1 2 PWM black PWM control input 1 3 Tach white Fan good fan bad evaluation n 1510 rpm high fan bad n 1620 rpm low fan good Isink max 10 mA 1 4 GND blue Reference ground Ite...

Страница 8: ...enance Switch off the device via the control input Do not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the power supply 5 MAINTENANCE MALFUNCTIONS PO...

Страница 9: ...noise acoustic At least every 6 months Replace device 5 3 Disposal For ebm papst environmental protection and resource preservation are top priority corporate goals ebm papst operates an environmenta...

Страница 10: ...pose of electronic components employing the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 53155 5 9970 ENU Change 202598 Approved 2020 01...

Отзывы: