Operating instructions
R1G225-AF11-14
Translation of the original operating instructions
3.2 Nominal data
Motor
M1G074-BF
Nominal voltage / VDC
48
Nominal voltage
range / VDC
36 .. 57
Frequency / Hz
-
Method of obtaining
data
fa
Speed (rpm) / min
-1
2700
Power consumption / W
95
Current draw / A
2.2
Min. ambient
temperature / °C
-25
Max. ambient
temperature / °C
60
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Technical description
Weight
1.6 kg
Size
225 mm
Motor size
74
Rotor surface
Painted black
Impeller material
PA plastic
Number of blades
7
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP44
Insulation class
"B"
Moisture (F) /
Environmental (H)
protection class
H2
Installation position
Any
Condensation
drainage holes
None
Mode
S1
Motor bearing
Ball bearing
Technical features
- Tach output
- Motor current limitation
- Soft start
- PWM control input
Electrical hookup
Connector with cable
Motor protection
Reverse polarity and locked-rotor
protection
with cable
Variable
Conformity with
standards
EN 60950-1
Approval
UL 1004-1; CSA C22.2 No. 77
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
;
Use the device in accordance with its degree of protection.
Information on surface quality
The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.
3.4 Mounting data
;
Secure the screws against unintentional loosening (e.g. use self-
locking screws).
For screw clearance, see Chapter 3.1 Product drawing
Strength class of
screws
8.8
Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.
3.5 Transport and storage conditions
Max. permitted
ambient temp. for
motor (transport/
storage)
+80 °C
Min. permitted
ambient temp. for
motor (transport/
storage)
-40 °C
3.6 Electromagnetic compatibility
EMC immunity to
interference
According to EN 61000-6-2 (industrial
environment)
EMC interference
emission
According to EN 55022 (Class B,
household environment)
Item no. 53155-5-9970 · ENU · Change 202598 · Approved 2020-01-07 · Page 5 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com