3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable PVC 3G 0.5mm², 3x crimped splices

2

Tightening torque for nuts to fasten fan housing or guard grille: 2.3 Nm

3

Tightening torque for screw to fasten fan impeller: 1.4 Nm

4

Tightening torque for nuts to fasten mounting bracket: 2.3 Nm

5

Direction of rotation counterclockwise, viewed toward shaft end

Item no. 11010-5-9970 · ENU · Change 202174 · Approved 2018-12-28 · Page 4 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание M4Q045-EF01-01

Страница 1: ...d maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work...

Страница 2: ...ny loose fitting or dangling clothing or jewelry while working on rotating parts Protect long hair with a cap WARNING Ejected parts If the motor is operated with attached fan blades missing protective...

Страница 3: ...with severe vibration oscillation This also includes vibration transmitted to the motor from the customer installation Operation in medical equipment with a life sustaining or life support function Co...

Страница 4: ...housing or guard grille 2 3 Nm 3 Tightening torque for screw to fasten fan impeller 1 4 Nm 4 Tightening torque for nuts to fasten mounting bracket 2 3 Nm 5 Direction of rotation counterclockwise view...

Страница 5: ...the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree of prote...

Страница 6: ...er supply matches the device voltage Only use cables designed for the current level indicated on the nameplate For determining the cross section note the sizing criteria according to EN 61800 5 1 The...

Страница 7: ...Connection diagram L blue PE green yellow N brown TOP thermal overload protector Item no 11010 5 9970 ENU Change 202174 Approved 2018 12 28 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673...

Страница 8: ...earings and allow any condensate that may have ingressed to evaporate Malfunction fault Possible cause Possible remedy Rotor not running smoothly Imbalance in rotating parts Clean the device replace i...

Страница 9: ...e mostly made of steel copper aluminum and plastic Metallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron...

Отзывы: