3.2 Nominal data

Motor

M4Q045-CF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Method of obtaining
data

me

me

Valid for approval/
standard

CE

CE

Speed (rpm) / min

-1

1300

1550

Power consumption / W

60

58

Power output / W

16

16

Current draw / A

0.42

0.36

Min. ambient
temperature / °C

-30

-30

Max. ambient
temperature / °C

40

40

Starting current / A

0.58

0.5

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

1.3 kg

Fan size

45 mm

Bearing shield material

Die-cast aluminum

Direction of rotation

Counterclockwise, viewed toward rotor

Degree of protection

IP42; installation- and position-dependent

Insulation class

"B"

Installation position

Any

Condensation
drainage holes

None

Mode

S1

Motor bearing

Calotte bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP)
internally connected

with cable

Lateral

Protection class

I (with customer connection of protective
earth)

Conformity with
standards

EN 60335-1; CE

Approval

EAC; VDE

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

3.4 Mounting data

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

Strength class of
screws

8.8

Any further mounting data required can be taken from the product drawing.

3.5 Transport and storage conditions

;

Use the device in accordance with its degree of protection.

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

4. CONNECTION AND STARTUP

4.1 Mechanical connection

WARNING
Hot motor housing

Risk of fire
→ Ensure that no combustible or flammable materials are

located close to the motor.

CAUTION
Cutting and crushing hazard when removing motor from
packaging

→ Carefully remove the device from its packaging. Strictly

avoid shocks.

→ Wear safety shoes and cut-resistant safety gloves.

;

Check the device for transport damage. Damaged devices are not to
be installed.

;

Install the undamaged device in accordance with your application.

CAUTION
Possible damage to the device

If the device slips during installation, serious damage can result.
→ Ensure that the device is securely positioned at its place of

installation until all fastening screws have been tightened.

4.2 Electrical connection

DANGER
Voltage on the device

Electric shock
→ Always connect a protective earth first.
→ Check the protective earth.

Item no. 10981-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 4 / 8

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание M4Q045-CF01-01

Страница 1: ...device may only be transported unpacked installed operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to inst...

Страница 2: ...e so it cannot slip e g by using a lashing strip 1 9 Storage Store the device partially or fully assembled in a dry and weatherproof manner in the original packaging in a clean environment Protect the...

Страница 3: ...using or guard grille 2 3 Nm 3 Tightening torque for screw for fastening fan impeller 1 4 Nm 4 Tightening torque for nut for fastening mounting bracket 2 3 Nm 5 Direction of rotation counterclockwise...

Страница 4: ...upport 3 4 Mounting data For screw clearance see Chapter 3 1 Product drawing Secure the screws against unintentional loosening e g use self locking screws Strength class of screws 8 8 Any further moun...

Страница 5: ...section is at least AWG 26 0 13 mm Ground conductor contact resistance according to EN 60335 Compliance with the impedance specifications according to EN 60335 for the protective earth connection cir...

Страница 6: ...4 Connection diagram L blue PE green yellow N brown TOP thermal overload protector Item no 10981 5 9970 ENU Change 89188 Approved 2016 04 18 Page 6 8 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673...

Страница 7: ...ating parts Clean the device replace it if imbalance persists after cleaning Motor not turning Mechanical blockage Switch off isolate from supply and remove mechanical blockage Line voltage faulty Che...

Страница 8: ...etallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron Aluminum Non ferrous metal e g motor windings Plast...

Отзывы: