3.2 Nominal data
Motor
M4Q045-CF
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Method of obtaining
data
me
me
Valid for approval/
standard
CE
CE
Speed (rpm) / min
-1
1300
1550
Power consumption / W
60
58
Power output / W
16
16
Current draw / A
0.42
0.36
Min. ambient
temperature / °C
-30
-30
Max. ambient
temperature / °C
40
40
Starting current / A
0.58
0.5
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Technical description
Weight
1.3 kg
Fan size
45 mm
Bearing shield material
Die-cast aluminum
Direction of rotation
Counterclockwise, viewed toward rotor
Degree of protection
IP42; installation- and position-dependent
Insulation class
"B"
Installation position
Any
Condensation
drainage holes
None
Mode
S1
Motor bearing
Calotte bearing
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP)
internally connected
with cable
Lateral
Protection class
I (with customer connection of protective
earth)
Conformity with
standards
EN 60335-1; CE
Approval
EAC; VDE
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
3.4 Mounting data
For screw clearance, see Chapter 3.1 Product drawing
;
Secure the screws against unintentional loosening (e.g. use self-
locking screws).
Strength class of
screws
8.8
Any further mounting data required can be taken from the product drawing.
3.5 Transport and storage conditions
;
Use the device in accordance with its degree of protection.
Max. permitted
ambient temp. for
motor (transport/
storage)
+ 80 °C
Min. permitted
ambient temp. for
motor (transport/
storage)
- 40 °C
4. CONNECTION AND STARTUP
4.1 Mechanical connection
WARNING
Hot motor housing
Risk of fire
→ Ensure that no combustible or flammable materials are
located close to the motor.
CAUTION
Cutting and crushing hazard when removing motor from
packaging
→ Carefully remove the device from its packaging. Strictly
avoid shocks.
→ Wear safety shoes and cut-resistant safety gloves.
;
Check the device for transport damage. Damaged devices are not to
be installed.
;
Install the undamaged device in accordance with your application.
CAUTION
Possible damage to the device
If the device slips during installation, serious damage can result.
→ Ensure that the device is securely positioned at its place of
installation until all fastening screws have been tightened.
4.2 Electrical connection
DANGER
Voltage on the device
Electric shock
→ Always connect a protective earth first.
→ Check the protective earth.
Item no. 10981-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 4 / 8