ebm-papst M4Q045-CF01-01 Скачать руководство пользователя страница 3

Operating instructions

M4Q045-CF01-01

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable PVC 0.5 mm², 3x crimped splices

2

Tightening torque for nut for fastening fan housing or guard grille 2.3 Nm

3

Tightening torque for screw for fastening fan impeller 1.4 Nm

4

Tightening torque for nut for fastening mounting bracket 2.3 Nm

5

Direction of rotation counterclockwise, viewed toward shaft end

Item no. 10981-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 3 / 8

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание M4Q045-CF01-01

Страница 1: ...device may only be transported unpacked installed operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to inst...

Страница 2: ...e so it cannot slip e g by using a lashing strip 1 9 Storage Store the device partially or fully assembled in a dry and weatherproof manner in the original packaging in a clean environment Protect the...

Страница 3: ...using or guard grille 2 3 Nm 3 Tightening torque for screw for fastening fan impeller 1 4 Nm 4 Tightening torque for nut for fastening mounting bracket 2 3 Nm 5 Direction of rotation counterclockwise...

Страница 4: ...upport 3 4 Mounting data For screw clearance see Chapter 3 1 Product drawing Secure the screws against unintentional loosening e g use self locking screws Strength class of screws 8 8 Any further moun...

Страница 5: ...section is at least AWG 26 0 13 mm Ground conductor contact resistance according to EN 60335 Compliance with the impedance specifications according to EN 60335 for the protective earth connection cir...

Страница 6: ...4 Connection diagram L blue PE green yellow N brown TOP thermal overload protector Item no 10981 5 9970 ENU Change 89188 Approved 2016 04 18 Page 6 8 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673...

Страница 7: ...ating parts Clean the device replace it if imbalance persists after cleaning Motor not turning Mechanical blockage Switch off isolate from supply and remove mechanical blockage Line voltage faulty Che...

Страница 8: ...etallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron Aluminum Non ferrous metal e g motor windings Plast...