4.4 Connection diagram

L

blue

PE

green/yellow

N

brown

Item no. 11483-5-9970 · ENU · Change 252384 · Approved 2022-06-08 · Page 7 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание M4Q045-BD03-04

Страница 1: ...d maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work...

Страница 2: ...ny loose fitting or dangling clothing or jewelry while working on rotating parts Protect long hair with a cap WARNING Ejected parts If the motor is operated with attached fan blades missing protective...

Страница 3: ...with severe vibration oscillation This also includes vibration transmitted to the motor from the customer installation Operation in medical equipment with a life sustaining or life support function Co...

Страница 4: ...housing or guard grille 2 3 Nm 3 Tightening torque for screw to fasten fan impeller 1 4 Nm 4 Tightening torque for nuts to fasten mounting bracket 2 3 Nm 5 Direction of rotation counterclockwise view...

Страница 5: ...E UKCA Approval CSA C22 2 No 77 EAC UL 1004 2 Use the device in accordance with its degree of protection Information on surface quality The surfaces of the products conform to the generally applicable...

Страница 6: ...for the current level indicated on the nameplate For determining the cross section note the sizing criteria according to EN 61800 5 1 The protective earth must have a cross section equal to or greater...

Страница 7: ...instructions 4 4 Connection diagram L blue PE green yellow N brown Item no 11483 5 9970 ENU Change 252384 Approved 2022 06 08 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phon...

Страница 8: ...ing the device CAUTION The motor restarts automatically when operating voltage is applied e g after a power failure Risk of injury Keep out of the motor s danger zone When working on the motor switch...

Страница 9: ...chnical knowledge The product is to be disassembled into suitable components for disposal employing standard procedures for motors WARNING Heavy parts of the product may drop off Some of the product c...