background image

Operating instructions

K3G400-AK11-H8

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Terminal box

2

Connector housing 3-pole GST18/3 Wieland 92.032.9058.1

2.1

N

2.2

PE

2.3

L

3

8-pole socket housing tyco 100616-2

4

8-pole socket housing tyco 100616-2

Item no. 54222-5-9970 · ENU · Change 211930 · Approved 2020-01-29 · Page 4 / 13

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание K3G400-AK11-H8

Страница 1: ...d specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazards associat...

Страница 2: ...g on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled into the...

Страница 3: ...ve devices Following the operating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e...

Страница 4: ...2 Connector housing 3 pole GST18 3 Wieland 92 032 9058 1 2 1 N 2 2 PE 2 3 L 3 8 pole socket housing tyco 100616 2 4 8 pole socket housing tyco 100616 2 Item no 54222 5 9970 ENU Change 211930 Approved...

Страница 5: ...evel The ErP data is determined using a motor impeller combination in a standardized measurement setup 3 4 Technical description Weight 8 9 kg Size 400 mm Motor size 84 Rotor surface Painted black Ele...

Страница 6: ...move the device from the packaging by grasping hold of the frame Never subject to any impact Wear safety shoes and cut resistant safety gloves NOTE Damage to the device from vibration Bearing damage s...

Страница 7: ...r integrated for compliance with EMC limits interference emission and immunity to interference reactive currents can be measured in the supply line even when the motor is at a standstill and the line...

Страница 8: ...RS485 RSA MODBUS RTU SELV 2 2 RSB Bus connection RS485 RSB MODBUS RTU SELV 2 3 GND Reference ground for control interface SELV 2 4 0 10 V Control input 2 5 10 V Fixed voltage output 10 VDC 2 6 RES Res...

Страница 9: ...interface SELV 3 4 0 10 V Control input 3 5 10 V Fixed voltage output 10 VDC 3 6 RES Reserve 3 7 COM Alarm COM 3 8 NC NC KL3 UMAX 24 V 3 9 Schirm Shield Item no 54222 5 9970 ENU Change 211930 Approved...

Страница 10: ...e with speed control or find another remedy Operation with excessively high vibration levels can lead to premature failure The maximum permissible vibration severity must not exceed 3 5 mm s and shoul...

Страница 11: ...overtemperature Deficient cooling Improve cooling Let the device cool down To reset the error message switch off the line voltage for at least 25 s and then switch it on again Thermal overload protect...

Страница 12: ...em which is certified in accordance with ISO 14001 and rigorously implemented around the world on the basis of German standards Right from the development stage ecological design technical safety and...

Страница 13: ...ploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 54222 5 9970 ENU Change 211930 Approved 2020 01 29 Page 13 13 ebm papst Mulfinge...

Отзывы: