Operating instructions
K3G310-RR18-R8
Translation of the original operating instructions
4.5 Connection diagram
No.
Conn.
Designation
Color
Function/assignment
1
1
L
black
Power supply, phase
1
2
N
blue
Power supply, neutral conductor
1
3
PE
green/
yellow
Protective earth
2
1
RSA
-
RS485 interface for MODBUS, RSA; SELV
2
2
RSB
-
RS485 interface for MODBUS, RSB; SELV
2
3
GND
-
Reference ground for control interface, SELV
2
4
0-10 V / PWM
-
Analog input (set value) SELV, 0-10 V, Ri = 100 kΩ, adjustable curve
2
5
+10 V
-
Fixed voltage output 10 VDC, SELV, +10 V +/-3%, max. 10 mA, short-circuit-proof, power
supply for external devices (e.g. potentiometers)
2
6
RES
-
Reserve
2
7
COM*
-
Alarm COM*
2
8
NC
-
NC KL2 UMAX 24 V
2
9
Schirm
-
Shield
3
1
RSA
-
RS485 interface for MODBUS, RSA; SELV
3
2
RSB
-
RS485 interface for MODBUS, RSB; SELV
Item no. 54490-5-9970 · ENU · Change 200267 · Approved 2019-02-14 · Page 8 / 12