background image

Operating instructions

K3G097-AS81-81

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable, halogen-free, railway application EN 45545, 2x 2.5 mm², 4x 1.0 mm²
6x wire-end ferrule

Item no. 53206-5-9970 · ENU · Change 265422 · Approved 2023-02-03 · Page 4 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание K3G097-AS81-81

Страница 1: ...ated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform w...

Страница 2: ...cure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry...

Страница 3: ...he device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibr...

Страница 4: ...g All dimensions in mm 1 Cable halogen free railway application EN 45545 2x 2 5 mm 4x 1 0 mm 6x wire end ferrule Item no 53206 5 9970 ENU Change 265422 Approved 2023 02 03 Page 4 10 ebm papst Mulfinge...

Страница 5: ...formation relates to this component s basic design The final protection class is based on the component s intended installation and connection If there is a PE connection point on the housing it must...

Страница 6: ...s place of installation until all fastening screws have been tightened The fan must not be strained on fastening 4 2 Electrical connection CAUTION Voltage The fan is a built in component and has no di...

Страница 7: ...4 V value of PWM signal is halved 4 0 10 V PWM yellow Control input Ri 47 k 0 10 V typ 1 V n 0 1 5 V n min 10 V n max PWM amplitude 10 V 1 50 kHz typ 5 n 0 15 n min 100 n max 5 DIAG white Diagnostic...

Страница 8: ...o not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the power supply 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repair...

Страница 9: ...months Replace device 5 3 Disposal For ebm papst environmental protection and resource preservation are top priority corporate goals ebm papst operates an environmental management system which is cert...

Страница 10: ...pose of electronic components employing the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 53206 5 9970 ENU Change 265422 Approved 2023 02...