background image

Operating instructions

G3G120-BB03-16

Translation of the original operating instructions

4.4 Connection screen

No.

Conn.

Designation

Colour

Function / assignment

2

L

brown

Power supply 230 VAC, 50-60 Hz, see type plate for voltage range

3

N

blue

Neutral conductor

1

PE

green/
yellow

Protective earth

7

0-10 V PWM

yellow

Control input 0 - 10 V or PWM, electrically isolated

5

Tach

white

Tach output: Open Collector, 1 pulse per revolution, electrically isolated

6

10V / max. 1.1
mA

red

Voltage output 10V / 1.1mA, electrically isolated, not short-circuit-proof

4

GND

blue

GND - Connection for control interface

Item no. 53586-5-9970 · ENG · Revision 82464 · Release 2015-05-07 · Page 7 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание G3G120-BB03-16

Страница 1: ...technical staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rul...

Страница 2: ...the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured Secure the device against accidental conta...

Страница 3: ...ng the operating instructions Improper use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or...

Страница 4: ...asures have the unit mm 1 Connection line PVC AWG20 3x lead tips crimped 2 Connection line PVC AWG22 4x lead tips crimped Item no 53586 5 9970 ENG Revision 82464 Release 2015 05 07 Page 4 10 ebm papst...

Страница 5: ...e with SELV potential safely disconnected from the mains Over temperature protected motor Touch current acc IEC 60990 measuring network Fig 4 TN system 3 5 mA Motor protection Thermal overload protect...

Страница 6: ...e of the device Only use cables designed for current according to the type plate For determining the cross section follow the basic principles in accordance with EN 61800 5 1 The protective earth must...

Страница 7: ...V PWM yellow Control input 0 10 V or PWM electrically isolated 5 Tach white Tach output Open Collector 1 pulse per revolution electrically isolated 6 10V max 1 1 mA red Voltage output 10V 1 1mA elect...

Страница 8: ...tage supply Start the device by changing the input signal 4 7 Switching off the device Switching off the device during operation Switch off the device via the control input Do not switch the motor e g...

Страница 9: ...and rectify cause of error if necessary cancel restart lock out Overtemperature of electronics motor Insufficient cooling Improve cooling Let the device cool down To reset the error message switch of...

Страница 10: ...east every 6 months Replace wires Condensate discharge holes for clogging as necessary Visual inspection At least every 6 months Open bore holes Item no 53586 5 9970 ENG Revision 82464 Release 2015 05...