3.2 Nominal data

Motor

M2D068-EC

Phase

3~

3~

3~

Nominal voltage / VAC

230

380

460

Nominal voltage
range / VAC

220 .. 380

Connection

Δ

Y

Y

Frequency / Hz

60

50

60

Type of data definition

ml

fa

ml

Valid for approval /
standard

UL 2111

CE

UL 2111

Speed / min

-1

2400

2250

2700

Power input / W

280

225

310

Current draw / A

0.36

Min. back pressure / Pa

100

0

200

Min. ambient temperature
/ °C

-25

-25

-25

Max. ambient
temperature
/ °C

-

-

60

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Technical features

Mass

4.3 kg

Size

146 mm

Material of terminal box

Die-cast aluminium

Material of impeller

Sheet steel, galvanised

Housing material

Die-cast aluminium

Material of guard grille

Hot-galvanised and spot-welded net

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 20; Depending on installation and
position

Insulation class

"F"

Humidity class

F1-1

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Electrical leads

Via terminal box

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 13912-5-9970 · Revision 82464 · Release 2014-04-07 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание G2D146-BF04-24

Страница 1: ...echnical staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rule...

Страница 2: ...lled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNING Depending on the installat...

Страница 3: ...ing the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Opening the terminal box during operat...

Страница 4: ...measures have the unit mm 1 Tightening torque 2 0 0 3 Nm 2 Cable diameter min 6 mm max 9 mm tightening torque 1 3 0 2 Nm Item no 13912 5 9970 Revision 82464 Release 2014 04 07 Page 4 10 ebm papst Mul...

Страница 5: ...idity class F1 1 Mounting position Any Condensate discharge holes None Operation mode S1 Motor bearing Ball bearing Touch current acc IEC 60990 measuring network Fig 4 TN system 0 75 mA Electrical lea...

Страница 6: ...h must have a cross section equal to or greater than the outer conductor cross section We recommend the use of 105 C cables Ensure that the minimum cable cross section is at least AWG26 0 13 mm Earth...

Страница 7: ...Cable routing for fans installed upright 4 3 4 Motor protection WARNING Device without overheating protection The device is delivered without any automatically functioning overheating protection The d...

Страница 8: ...phase motor Y Star connection Delta connection L1 U1 blue L2 V1 black L3 W1 brown U2 white V2 green W2 yellow Item no 13912 5 9970 Revision 82464 Release 2014 04 07 Page 8 10 ebm papst Mulfingen GmbH...

Страница 9: ...the supply line When disconnecting be sure to disconnect the earth wire connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Return the dev...

Страница 10: ...l inspection At least every 6 months Repair or replacement of the device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting...

Отзывы: