3. TECHNICAL DATA

3.1 Product drawing

All measures have the unit mm.

1

Housing side parts sealed with NBR round cord (pentane-resistant)

2

3-pole strip, mating connector: (not included in standard scope of delivery) tyco No. 350 766-1; female terminal: tyco No. 926 884-1

2.1

L

2.2

N

2.3

PE

3

5-pole strip; mating connector (not included in delivery) Molex No. 39-01-4050, female connector Molex No. 39-00-0059

3.1

(+)

3.2

Speed monitoring

3.3

Not assigned

3.4

PWM input

3.5

(-) GND

4

Closed bleeder connection for pressure relief (drilled open if necessary)

Item no. 51289-5-9970 · Revision 79946 · Release 2013-12-02 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание G1G144-AF25-01

Страница 1: ...authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards...

Страница 2: ...rically live parts Escaping gas may also cause explosions Never open the blower WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the devic...

Страница 3: ...ems Installing the device into an overall system for moving air Commissioning the built in component only after installation in the customer unit Operating the device with all protective features in p...

Страница 4: ...1 female terminal tyco No 926 884 1 2 1 L 2 2 N 2 3 PE 3 5 pole strip mating connector not included in delivery Molex No 39 01 4050 female connector Molex No 39 00 0059 3 1 3 2 Speed monitoring 3 3 No...

Страница 5: ...le for pre mixture Motor bearing Ball bearing Technical features Tach output Motor current limit Control input PWM Touch current acc IEC 60990 measuring network Fig 4 TN system 3 5 mA Motor protection...

Страница 6: ...inst accidental contact is provided Before working on the electrical connection the connections to the mains supply and PE must be shorted CAUTION Electrical voltage The device is a built in component...

Страница 7: ...n be switched off using an all pole disconnecting switch When working on the device you must switch off the system machine in which the device is installed and secure it from being switched on again C...

Страница 8: ...iginal operating instructions 4 4 Connection screen Item no 51289 5 9970 Revision 79946 Release 2013 12 02 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 F...

Страница 9: ...y 0 PWM to the PWM control input if you are using the PWM control input Apply the nominal voltage to the voltage supply Start the device by changing the input signal 4 7 Switching off the device Switc...

Страница 10: ...if imbalance is still evident after cleaning replace the device If you have attached any weight clips during cleaning make sure to remove them afterwards Motor does not turn Mechanical blockage Switc...

Страница 11: ...l inspection At least every 6 months Fasten Mounting of protective earth connection Visual inspection At least every 6 months Fasten Check the insulation of the wires for damage Visual inspection At l...

Отзывы: