3. TECHNICAL DATA

3.1 Product drawing

All measures have the unit mm.

1

Direction of air flow "V"

2

Depth of screw max. 10 mm

3

Tightening torque 1.5±0.2 Nm

4

Cable diameter min. 4 mm, max. 10 mm, tightening torque 2.5±0.4 Nm

Item no. 50611-5-9970 · ENG · Revision 211129 · Release 2020-07-14 · Page 4 / 13

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание A3G630-AD03-A8

Страница 1: ...st run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re evaluated once it is installed in the e...

Страница 2: ...Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured Secure the device against acc...

Страница 3: ...Operating the device with an imbalance e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also include vibrations that are transmitted from the customer system...

Страница 4: ...Direction of air flow V 2 Depth of screw max 10 mm 3 Tightening torque 1 5 0 2 Nm 4 Cable diameter min 4 mm max 10 mm tightening torque 2 5 0 4 Nm Item no 50611 5 9970 ENG Revision 211129 Release 2020...

Страница 5: ...ata is determined using a motor impeller combination in a standardised measurement configuration 3 4 Technical features Mass 5 9 kg Size 630 mm Motor size 84 Surface of rotor Coated in black Material...

Страница 6: ...shoes and cut resistant safety gloves CAUTION The blades of the impeller could be damaged Set down the fan carefully on a soft surface Make sure the blades are not subjected to load After installation...

Страница 7: ...al current device RCD is required in your installation only universal residual current devices type B or B are permissible Residual current devices RCD cannot provide personal safety while operating t...

Страница 8: ...The cables must always be routed downwards Fig 3 Cable routing for fans installed upright 4 4 Factory settings Factory settings with which the device is pre set by ebm papst Operation mode PWM contro...

Страница 9: ...normally closed connection 2 A max 250 VAC min 10 mA 1 6 NC white 2 Floating status message contact normally closed connection 2 8 0 10 V yellow Control input set value 0 10 VDC impedance 100 kOhm SE...

Страница 10: ...to devices which have already been equipped with plugs and terminals or similar connectors by the customer WARNING Hot motor housing Fire hazard Ensure that no combustible or flammable materials are...

Страница 11: ...ance in rotating parts Clean the device if imbalance is still evident after cleaning replace the device If you have attached any weight clips during cleaning make sure to remove them afterwards Motor...

Страница 12: ...osal For ebm papst environmental protection and resource preservation are top priority corporate goals ebm papst operates an environmental management system which is certified in accordance with ISO 1...

Страница 13: ...ploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 50611 5 9970 ENG Revision 211129 Release 2020 07 14 Page 13 13 ebm papst Mulfing...

Отзывы: