ebm-papst A3G450-BL03-H6 Скачать руководство пользователя страница 8

Operating instructions

A3G450-BL03-H6

Translation of the original operating instructions

Set value requirement

Analog (linear)

Direction of action
parameter set 1

Positive (heating)

Direction of action
parameter set 2

Positive (heating)

Item no. 53897-5-9970 · ENU · Change 211129 · Approved 2020-07-14 · Page 8 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание A3G450-BL03-H6

Страница 1: ...cialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazards associated wi...

Страница 2: ...y that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accide...

Страница 3: ...ctions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation...

Страница 4: ...e of seal provided Cable diameter min 4 mm max 10 mm tightening torque 1 8 0 3 Nm 4 Cable diameter min 6 mm max 10 mm tightening torque 1 8 0 3 Nm use must be made of seal provided Cable diameter min...

Страница 5: ...otor impeller combination in a standardized measurement setup 3 4 Technical description Weight 4 8 kg Size 450 mm Motor size 84 Rotor surface Painted black Electronics housing material Die cast alumin...

Страница 6: ...only the blades near the hub Strictly avoid shocks Wear safety shoes and cut resistant safety gloves CAUTION The blades of the impeller could be damaged Carefully set down the fan on a soft surface M...

Страница 7: ...rotective earth ensure sufficient additional corrosion protection 4 2 2 Reactive currents Because of the EMC filter integrated for compliance with EMC limits interference emission and immunity to inte...

Страница 8: ...ear Direction of action parameter set 1 Positive heating Direction of action parameter set 2 Positive heating Item no 53897 5 9970 ENU Change 211129 Approved 2020 07 14 Page 8 12 ebm papst Mulfingen G...

Страница 9: ...act common connection contact rating 250 VAC 2 A AC1 min 10 mA basic insulation on supply side and reinforced insulation on control interface side 8 GND Reference ground for control interface SELV 9 R...

Страница 10: ...ound connection last 5 INTEGRATED PROTECTIVE FEATURES The integrated protective functions cause the motor to switch off automatically in the event of the faults described in the table Fault Safety fea...

Страница 11: ...oaking installation in the barn they have to be manually soaked separately using a hosepipe or knapsack sprayer for example Instructions for cleaning Fig 1 Cleaning of the fan with a high pressure cle...

Страница 12: ...to be heeded 6 3 2 Disassembly Disassembly of the product must be performed or supervised by qualified personnel with the appropriate technical knowledge The product is to be disassembled into suitab...