PS2248-HV Cabinet Power Supply
Operations Manual
Eberle Design Inc.
Page 2
1.3.4 ENVIRONMENTAL
Operating Temperature Range ........................................................................ -34 to +74
o
C
Storage Temperature Range ........................................................................... -45 to +85
o
C
Humidity (non-condensing) ....................................................................... 0 to 95% Relative
1.4 DC CONNECTOR
The output connector is a Phoenix Contact #1825161 and mates with a Phoenix Contact
#1825352 or equivalent. Pin #1 is the right most pin when viewed from the rear of the
supply.
Pin Function
1
+48VDC
2
48VDC Ground**
3
+24VDC
4
Reserved
5
24VDC Ground
6
Chassis Ground
**NOTE
The 48 VDC output is electrically isolated from the AC Line
input and the 24VDC output. The
48VDC Ground
(pin #2) must
be connected within the cabinet to the Cabinet Monitor Unit
(CMUip-2212-LV) MAINS GROUND pin B32.